Vapour-Liquid-Liquid-Equilibrium Determination Apparatus FISCHER® LABODEST® VLE 602, designed/produced according to Patent ES 2 187 220 B2 of University of Alicante

JMG No. 1431277 • MPN 108111

0.0

Call for Price

Overview
The vapour-liquid equilibrium data are able to be measured and determined with two-component or multi-component systems forming two phase (vapour-liquid) or three phase (vapour-liquid- liquid) mixtures. The unit can be applied for measuring equilibrium data and evaluation of equilibrium curves. These curves are for example used for the calculation of the separation efficiency of distillation columns. The VLLE-apparatus can also be operated as VLE-apparatus. The ultrasonic generator for homogenisation of the liquid phases can be removed easily. Built with microprocessor controller for precise and reliable operation. Technical Data Operation Pressure VLLE: Atmospheric VLE: Atmospheric (others: see Options) Operation Temperature VLLE: Up to 100°C VLE: Up to 180°C (others: see Options) Operating Volume 80.. .100 ml Measurement Volume 40... 50 ml Mains Supply 230 V, 50 Hz Dimensions (Lx Dx H) 0.95 x 0.60 x 1.10 m   The system consists of: - 1 x mounting frame for all unit parts, including all holders, fully housed with polycarbonate screens and aluminium sheets. The polycarbonate screens at the side do have hand holes for operation of the valves without opening the safety-housing. The polycarbonate doors in front are divided into sections. Only one door needs to be opened for taking samples. - 1 x glass apparatus, complete with silvered vacuum mantle, cooler, circulation evaporator and vacuum-tight screwing for sample take-off by means of a syringe, alternative sample take off with solenoid operated valves - 1 x immersion heater 350 W, with antibumping surface finish - 1 x magnetic stirrer for intensive mixing - 10 x final receivers with screw caps, approx. 5 ml, for operation under atmospheric conditions, vacuum and overpressure - 1 x feed burette, 250 ml, graduated, plastic coated - 2 x solenoid coils - 1 x liquid thermometer Pt- 100 - 1 x vapour thermometer Pt- 100 - 1 x ultrasonic generator for the homogenisation of two liquid phases - 2 x gastight syringe 10 uL - 1 x Phase Equilibrium Controller FISCHER® [VLLE] with modem micro-electronics, offers high operating comfort, safety and reliability, with menu guided operation by touch panel Can be connected to a PC for data display and data storage by means of an interface (see Item 10 and 11).     Following functions are available:     - vapour temperature display:     range: 0...250°C     accuracy: ± 0.1 K if calibrated (see calibration of vapour temp sensor)     resolution: 0.01 K     - liquid temperature display:     range: 0...250°C     - pressure/vacuum display and control:     accuracy of measurement: 0...l bar abs.: ± 1 mbar if calibrated (see calibration of pressure sensor 0-1013mbar)                                            1 . . .4 bar abs.: ± 4 mbar if calibrated (see calibration of pressure sensor 0-4000mbar)     - heating power preset for evaporator (0... 100%)     - controlling of the solenoids for sample take-off (manually)      Electrical Supply: 230 V, 50 Hz   Important remarks for analysis of VLL (vapour-liquid-liquid) systems - see bottom of quote  
0.0

0 reviews

Add to your favourites
Overview
The vapour-liquid equilibrium data are able to be measured and determined with two-component or multi-component systems forming two phase (vapour-liquid) or three phase (vapour-liquid- liquid) mixtures. The unit can be applied for measuring equilibrium data and evaluation of equilibrium curves. These curves are for example used for the calculation of the separation efficiency of distillation columns. The VLLE-apparatus can also be operated as VLE-apparatus. The ultrasonic generator for homogenisation of the liquid phases can be removed easily. Built with microprocessor controller for precise and reliable operation. Technical Data Operation Pressure VLLE: Atmospheric VLE: Atmospheric (others: see Options) Operation Temperature VLLE: Up to 100°C VLE: Up to 180°C (others: see Options) Operating Volume 80.. .100 ml Measurement Volume 40... 50 ml Mains Supply 230 V, 50 Hz Dimensions (Lx Dx H) 0.95 x 0.60 x 1.10 m   The system consists of: - 1 x mounting frame for all unit parts, including all holders, fully housed with polycarbonate screens and aluminium sheets. The polycarbonate screens at the side do have hand holes for operation of the valves without opening the safety-housing. The polycarbonate doors in front are divided into sections. Only one door needs to be opened for taking samples. - 1 x glass apparatus, complete with silvered vacuum mantle, cooler, circulation evaporator and vacuum-tight screwing for sample take-off by means of a syringe, alternative sample take off with solenoid operated valves - 1 x immersion heater 350 W, with antibumping surface finish - 1 x magnetic stirrer for intensive mixing - 10 x final receivers with screw caps, approx. 5 ml, for operation under atmospheric conditions, vacuum and overpressure - 1 x feed burette, 250 ml, graduated, plastic coated - 2 x solenoid coils - 1 x liquid thermometer Pt- 100 - 1 x vapour thermometer Pt- 100 - 1 x ultrasonic generator for the homogenisation of two liquid phases - 2 x gastight syringe 10 uL - 1 x Phase Equilibrium Controller FISCHER® [VLLE] with modem micro-electronics, offers high operating comfort, safety and reliability, with menu guided operation by touch panel Can be connected to a PC for data display and data storage by means of an interface (see Item 10 and 11).     Following functions are available:     - vapour temperature display:     range: 0...250°C     accuracy: ± 0.1 K if calibrated (see calibration of vapour temp sensor)     resolution: 0.01 K     - liquid temperature display:     range: 0...250°C     - pressure/vacuum display and control:     accuracy of measurement: 0...l bar abs.: ± 1 mbar if calibrated (see calibration of pressure sensor 0-1013mbar)                                            1 . . .4 bar abs.: ± 4 mbar if calibrated (see calibration of pressure sensor 0-4000mbar)     - heating power preset for evaporator (0... 100%)     - controlling of the solenoids for sample take-off (manually)      Electrical Supply: 230 V, 50 Hz   Important remarks for analysis of VLL (vapour-liquid-liquid) systems - see bottom of quote  

DETAILS

The vapour-liquid equilibrium data are able to be measured and determined with two-component
or multi-component systems forming two phase (vapour-liquid) or three phase (vapour-liquid-
liquid) mixtures. The unit can be applied for measuring equilibrium data and evaluation of
equilibrium curves. These curves are for example used for the calculation of the separation
efficiency of distillation columns.

The VLLE-apparatus can also be operated as VLE-apparatus. The ultrasonic generator for
homogenisation of the liquid phases can be removed easily.

Built with microprocessor controller for precise and reliable operation.

Technical Data


Operation Pressure VLLE: Atmospheric
VLE: Atmospheric (others: see Options)
Operation Temperature VLLE: Up to 100°C
VLE: Up to 180°C (others: see Options)
Operating Volume 80.. .100 ml
Measurement Volume 40... 50 ml
Mains Supply 230 V, 50 Hz
Dimensions (Lx Dx H) 0.95 x 0.60 x 1.10 m

 

The system consists of:
- 1 x mounting frame for all unit parts, including all holders, fully housed with polycarbonate
screens and aluminium sheets. The polycarbonate screens at the side do have hand holes
for operation of the valves without opening the safety-housing. The polycarbonate doors
in front are divided into sections. Only one door needs to be opened for taking samples.
- 1 x glass apparatus, complete with silvered vacuum mantle, cooler, circulation evaporator and
vacuum-tight screwing for sample take-off by means of a syringe, alternative sample take
off with solenoid operated valves
- 1 x immersion heater 350 W, with antibumping surface finish

- 1 x magnetic stirrer for intensive mixing
- 10 x final receivers with screw caps, approx. 5 ml, for operation under atmospheric conditions,
vacuum and overpressure

- 1 x feed burette, 250 ml, graduated, plastic coated
- 2 x solenoid coils
- 1 x liquid thermometer Pt- 100
- 1 x vapour thermometer Pt- 100
- 1 x ultrasonic generator for the homogenisation of two liquid phases
- 2 x gastight syringe 10 uL

- 1 x Phase Equilibrium Controller FISCHER® [VLLE] with modem micro-electronics, offers
high operating comfort, safety and reliability, with menu guided operation by touch panel
Can be connected to a PC for data display and data storage by means of an interface (see
Item 10 and 11).

    Following functions are available:
    - vapour temperature display:
    range: 0...250°C
    accuracy: ± 0.1 K if calibrated (see calibration of vapour temp sensor)
    resolution: 0.01 K
    - liquid temperature display:
    range: 0...250°C
    - pressure/vacuum display and control:
    accuracy of measurement: 0...l bar abs.: ± 1 mbar if calibrated (see calibration of pressure sensor 0-1013mbar)
                                           1 . . .4 bar abs.: ± 4 mbar if calibrated (see calibration of pressure sensor 0-4000mbar)
    - heating power preset for evaporator (0... 100%)
    - controlling of the solenoids for sample take-off (manually) 
    Electrical Supply: 230 V, 50 Hz

 

Important remarks for analysis of VLL (vapour-liquid-liquid) systems - see bottom of quote

 

REVIEWS

1300 501 555

Estimated Delivery:

6-8 Weeks

In stock Items under 5Kg usually dispatched within 48 hrs Under 30Kg delivery $30.00 flat rate
Freight Costs include local Australian Voltage and Earth Leakage testing as well as inclusion of an Australian Standard Plug.
PMA, T&C's, warranty & returns Click Here Ask us for our Preventative Maintenance Agreement (PMA)