GDS’ Wet-wet differential pressure transducer kit is available in 50kPa and 200kPa differential ranges as standard, accepting line pressure up to 10MPa. Mounted on a polished stainless steel plate with a 4-way crossover valve; this allows for safe filling/de-airing with high and low sides of the transducer connected, as well as offering a simple single valve adjustment to isolate the transducer during a test should the effective stress used in the system need to be increased higher than the differential range.