PR-701BZ / Platinum reference Electrode, Remarks:Platinum Combination Electrode.Standard; 0.6m cable, Category: Electrode, for model: COM-300A/COM-A19, v25.4_2318874
Representative image only

Hitachi PR-701BZ Platinum-Reference Electrode, 0.6 m

$949.30

The price is inclusive of GST

The Hitachi PR-701BZ Platinum-Reference Electrode, 0.6 m (HIRAN-D254705-A) is a general-purpose combination electrode for potentiometric redox titration. It combines platinum indicator and reference functions in one assembly, with a 0.6 m cable, 4M KCl internal solution and compatibility with COM-300A and COM-A19 automatic titrators.

Key Features

  • Designed for redox titration, supporting potentiometric analysis of oxidation-reduction reactions
  • Integrated platinum-reference construction, combining indicator and reference electrode functions within one assembly
  • General-purpose configuration, suitable for routine redox titration applications
  • Supports common redox analytes, including metal ions, iodine and hydrogen peroxide
  • Broad operating temperature range, suitable for test solutions from -5 to 100°C
  • 4M potassium chloride internal solution, providing the specified reference-electrode filling solution
  • Standard 0.6 m connection cable, supporting connection to the compatible titrator system
  • Compact electrode construction, measuring approximately 135 mm long and 12 mm in diameter
  • Defined upper-cap dimensions, measuring approximately 25 mm long and 16 mm in diameter
  • Verified titrator compatibility, specified for Hitachi Hiranuma COM-300A and COM-A19 systems

Benefits

  • Combines platinum sensing and reference functions to reduce the number of separate electrodes required in the holder.
  • Supports routine endpoint detection across a range of oxidation-reduction titration procedures.
  • Accommodates varied sample conditions through its -5 to 100°C operating range.
  • Maintains compatibility with established COM-300A and COM-A19 titration configurations.
  • Simplifies replacement planning through clearly defined cable length, internal solution and physical dimensions.

Why Choose the Hitachi PR-701BZ Platinum-Reference Electrode, 0.6 m (HIRAN-D254705-A)?

The PR-701BZ provides the integrated platinum-reference construction and broad operating range required for general-purpose redox titration. Its verified physical configuration and compatibility with COM-300A and COM-A19 titrators make it suitable for maintaining established Hitachi Hiranuma analytical systems. John Morris Group can assist with confirming the electrode connection and complete titration configuration.

Over 40,000 Customers Trust John Morris