PR-731BZ / Platinum reference Electrode, Remarks:Platinum Combination Electrode.Standard; 0.6m cable, Category: Electrode, for model: COM-300A/COM-A19, v25.4_2318876
Representative image only

Hitachi HIRANUMA PR-731BZ Platinum Combination Electrode

$979.00

The price is inclusive of GST

The Hitachi HIRANUMA PR-731BZ Platinum Combination Electrode (D254706-A; JMG code HIRAN-D254706-A) combines platinum indicator and reference-electrode functions for redox titration in test tubes or closed cells. It has a -5 to 100°C operating range, uses 4M KCl inner solution and includes a 0.6 m cable.

Key Features

  • Combined platinum and reference-electrode design, integrating both measurement functions into one assembly
  • Designed for redox titration, supporting oxidation-reduction endpoint detection
  • Suitable for multiple redox analytes, including metal ions such as Cu2+ and Fe3+, iodine and hydrogen peroxide
  • Suitable for test tubes and closed cells, providing a dedicated configuration for compact vessels
  • Minimum vessel diameter of 18 mm, as specified for compatible test tubes and closed cells
  • Maximum vessel height of 105 mm, based on the manufacturer’s stated vessel requirements
  • Broad operating temperature range, specified from -5 to 100°C
  • 4M potassium chloride inner solution, as specified for the PR-731BZ configuration
  • Integrated 0.6 m cable, providing connection reach around the titration station
  • Slender lower electrode shaft, measuring 100 mm long and 8 mm in diameter
  • Defined body dimensions, with a 165 mm body length, 16 mm collar diameter and 25 mm collar height
  • Dedicated HIRANUMA titrator accessory, with COM-300A and COM-A19 compatibility listed by John Morris Group

Note: Confirm the instrument connection, vessel dimensions and inner-solution requirements for the intended titration method before ordering.

Benefits

  • Reduces the number of separate electrodes required by combining platinum indicator and reference functions.
  • Supports redox titration in compact test tubes and closed cells where available vessel space is limited.
  • Provides defined vessel and electrode dimensions to simplify configuration planning.
  • Supports a broad range of compatible sample temperatures through its -5 to 100°C operating range.
  • Helps reduce replacement errors through clear PR-731BZ and D254706-A identification.

Why Choose the Hitachi HIRANUMA PR-731BZ Platinum Combination Electrode (D254706-A)?

The PR-731BZ provides an integrated platinum-reference electrode configuration for redox titration in test tubes and closed cells. John Morris Group can assist with confirming COM-300A or COM-A19 compatibility and suitability for the intended vessel and titration method.