GRT-603BZ / Glass - Reference - Thermistor Electrode, Remarks:Glass Combination Electrode.Standard; 0.6m cable, Category: Electrode, for model: COM-300A/COM-A19, v25.4_2318880
Representative image only

Hitachi GRT-603BZ Glass-Reference Thermistor Electrode

$1,127.50

The price is inclusive of GST

The Hitachi GRT-603BZ Glass-Reference Thermistor Electrode (D254708-A) is a combination electrode for neutralisation titration with compatible HIRANUMA automatic titrators. It integrates glass sensing, reference and thermistor functions in one electrode, with temperature compensation, a 0 to 80°C operating range and a 0.6 m cable.

Key Features

  • Three integrated electrode functions, combining glass sensing, reference and thermistor elements in one assembly
  • Designed for neutralisation titration, supporting potentiometric analysis of acids and bases
  • Integrated temperature compensation, allowing sample-temperature effects to be accounted for during pH-based measurements
  • 0 to 80°C operating range, provided the sample solution remains unfrozen
  • 4 M potassium chloride inner solution, providing the specified internal reference electrolyte
  • 600 mm connection cable, equivalent to the listed 0.6 m cable length
  • Suitable for common acid and base analytes, including hydrochloric acid, sulphuric acid, nitric acid and sodium hydroxide
  • Listed for COM-300A and COM-A19 titrators, supporting replacement selection for these instrument models
  • Dedicated HIRANUMA titrator accessory, developed for compatible automatic potentiometric titration systems
  • Not available for COM-28 or COM-28S, helping prevent selection for an incompatible titrator series

Note: Confirm the instrument connector, electrode-holder arrangement and required calibration solutions before ordering. This model is not available for COM-28 or COM-28S titrators.

Benefits

  • Reduces the number of separate components required by combining pH sensing, reference and temperature measurement functions.
  • Conserves space in the electrode holder during neutralisation titration.
  • Supports temperature-compensated measurements without requiring a separate thermistor electrode.
  • Simplifies replacement selection through its defined model, part number, cable length and titrator compatibility.
  • Provides practical connection reach through the integrated 0.6 m cable.

Why Choose the Hitachi GRT-603BZ Glass-Reference Thermistor Electrode (D254708-A)?

The Hitachi GRT-603BZ Glass-Reference Thermistor Electrode (D254708-A) combines the principal electrode functions required for temperature-compensated neutralisation titration in one compact assembly. John Morris Group can assist with confirming compatibility with the COM-300A, COM-A19 and the intended titration method.

Over 40,000 Customers Trust John Morris