Setaflash Series 3 Flash Point Tester

Cup materialAluminium
Gas SupplyLaboratory gas, 3kPa (0.44psi) maximum pressure or Butane from optional Portable Gas Tank 13667-0
Heating and Cooling systemsCartridge heater
Power200W (maximum)
Ramp rate2°C/min ramp
Sample Size2ml for flash points up to 100°C 4ml for flash points above 100°C
Size (HxWxD)19.5 x 29.5 x 14cm
Temperature RangeAmbient to 300°C (0° to 300°C with 13870-0)
Test duration, Rapid Equilibrium Mode1 minute below 100°C, 2 minutes above 100°C, or user determined 1 to 99 minutes
Test modesRapid Equilibrium and Ramp
Voltage110/120V or 220/240V, 50/60Hz (switchable) 12Vdc with optional adaptor
Weight3 kg
In-Service_Lubricants
Paint_Chemicals
Petroleum
Pharmaceuticals
Series_3
Setaflash_flashpoint_testing_brochure
Small-Scale-vs-Pensky-Martens
Overview

The Setaflash Series 3 Plus Closed Cup Flash Point Tester is an easy to use Small Scale Flash Point instrument that can complete a flash/no-flash test in less than two minutes, or determine the flash point of a sample within a temperature range of 0° to 300°C.

All functions on the Series 3 flash point tester are accessed via a two button keypad and the Seta Multifunctional And Rotational Test (SMART) control feature. The digital display shows test parameters, instrument status, and the test result. An audible prompt is sounded when an action is required from the operator. An automatic flash detector reduces the chance of misinterpretation of the test result by the operator, and enhances repeatability.

Gas for the test jet/shutter assembly is supplied from an integral gas tank, which is filled using a standard butane (lighter) refill cartridge. The instrument is lightweight and suitable for mobile use when operated from the optional 12 volt power supply adaptor.

The temperature ramp mode allows rapid determination of the flash point of a sample. The cup is heated at a rate of 2°C per minute from the start temperature. An audible prompt to carry out a flash test occurs every 1°C rise up to 100°C, every 2°C rise over 100°C. If no flash is detected when the temperature reaches 40°C above the start temperature, the flash tester automatically terminates the test.

Supplied with: 2ml syringe, ignitor, mains lead, and instruction manual.