Erlab

Erlab

Founded in 1968 in France, Erlab® is a global pioneer in air filtration technology, having invented the world’s first ductless fume hood. With over 50 years of research and development, they have established themselves as a leader in laboratory safety, focusing on protecting both the user and the environment through innovative, HVAC-independent solutions. As the authorised Australian partner, we provide local research facilities and industrial labs with direct access to these sustainable technologies, which are critical for maintaining safety standards within the Laboratory sector across Australia and New Zealand.

Erlab engineering is defined by the "Green Chemistry" philosophy, offering modular filtration systems that eliminate the need for complex ductwork and high energy consumption. Their signature Captair Smart and GreenFumeHood technologies utilise high-efficiency carbon and HEPA filters to trap hazardous gases and particulates at the source. We back these advanced safety systems with factory-trained technicians and local technical guidance to help you integrate ergonomic and energy-efficient protection into your modern laboratory workflow.

Technical Applications for Erlab in Australia

In Australian chemical and biological research, maintaining high-performance containment without the infrastructure costs of traditional ducted systems is a significant operational advantage. The Erlab Captair 321 Smart Ductless Filtering Fume Hood provides a standalone solution that can be easily relocated, ensuring flexible lab configurations. To enhance visibility and durability, these units often incorporate high-quality Safety glass panels, allowing researchers to monitor sensitive reactions safely while benefiting from superior impact resistance.

For laboratories focused on air quality management and hazardous vapour extraction, the Erlab Captair S321 Smart Fume Extractor offers targeted protection for point-of-use applications. In facilities requiring continuous air purification, the Erlab Halo C Chemplus with Sensor A ceiling-mounted system provides autonomous monitoring and filtration of the laboratory ambient air. For researchers who prefer integrated visual feedback, the Erlab Captair 321 Smart with Screen provides real-time alerts and filter status directly on the unit, helping Australian labs achieve strict compliance with occupational health and safety regulations.

Why Source Erlab from John Morris Group?

  • Inventor of Ductless Technology: Benefit from over 50 years of expertise from the original pioneer of ductless filtration, ensuring the most refined and proven safety systems available.
  • Advanced Smart Technology: Features intuitive light-based communication and sensor alerts for filter saturation, door status, and airflow, allowing for safe, unattended operation.
  • Superior Energy Efficiency: Standalone systems eliminate the need for expensive HVAC ducting and conditioned air exhaust, significantly reducing the carbon footprint and operating costs of your lab.
  • Flexible Modular Filtration: Captair systems can be configured with various filter types, including HEPA, ULPA, and specialized carbon, to handle specific chemical or biological hazards.
  • Remote Monitoring Ecosystem: Integrated mobile apps allow lab managers to monitor the safety status of multiple hoods and storage cabinets remotely, ensuring 24/7 protection.

We back this world-leading safety range with over 70 years of local experience, providing Australian laboratories with factory-trained service, filter replacement programs, and dedicated application support.

Frequently Asked Questions

How do ductless fume hoods compare to traditional ducted systems?
Ductless fume hoods filter air and recirculate it back into the laboratory, eliminating the need for expensive HVAC connections and the loss of conditioned air. They are significantly more energy-efficient and offer greater flexibility, as they can be moved within the laboratory without requiring new infrastructure.

How often do the filters need to be replaced in an Erlab hood?
Filter life depends on the frequency of use and the types of chemicals handled. Erlab systems include integrated sensors that monitor filter saturation in real-time, providing visual and audible alerts when a replacement is required. Our local team also offers an "eGuard" service to help predict and manage filter life.

Can Erlab hoods handle both powders and chemical vapours?
Yes, the filtration modules can be stacked to include both a HEPA filter for particulates (powders) and a carbon filter for chemical vapours. This molecular filtration capability ensures comprehensive protection across a wide variety of laboratory applications.

What is the benefit of the Halo C air purification system?
The Halo C is a ceiling-mounted unit that constantly filters the air in the lab. It is equipped with sensors that detect chemical vapours in the ambient air; if a spill or leak occurs, it automatically increases its filtration speed to rapidly decontaminate the room.

Is the safety glass used in Erlab enclosures resistant to chemicals?
The safety glass used is highly resistant to a broad range of common laboratory acids and solvents. It is designed to maintain clarity over years of use and provides a robust physical barrier that meets international safety standards for laboratory enclosures.

Does John Morris Group provide local validation and testing for these hoods?
We provide comprehensive local support, including on-site installation, commissioning, and regular face-velocity testing. Our factory-trained technicians ensure that your filtration system is operating according to manufacturer specifications and relevant Australian safety standards.