The new Droplet Size Analyser 2.0 introduces a completely new user interface, GoScan for Minispec, with the possibility to characterize multimodal droplet size distributions and further imporve the results for unimodal distributions where a lognormal shape is assumed.
- Standard TD-NMR system for the determination of the oil and water droplet size distribution in emulsions (oil-in-water: Mayonnaise; water-in-oil: Margarine, Diet Spreads and related products) running the new G-Var method.
The minispec mq-Series are flexible TD-NMR Analyzers and can potentially also be used for other applications, of course depending upon system configuration. The minispec mq20 oil & water droplet size analyzer, accommodates sample tubes of 10 mm outer diameter and can also be utilized for diffusion and relaxation time measurements. It consists of:
The minispec mq20 Water/Oil Droplet Size Analyzer (230 V/50 Hz)
minispec mq control unit (NF series), E1452120_01, with broad band transmitter, consisting of:
- Electronics Unit Housing: EMI-shielded, CE-conform, closed housing, maintenance-free, air-cooled, wide-line power supply, LEDs for convenient diagnosis (power-on, connection).
- Central Processor Unit (CPU): Embedded CPU with real-time processor unit, dynamic RAM and Flash-ROM for firmware. 100 Mbit Ethernet adapter to host PC. Fully featured remote control via minispec software.
- Direct-Digital RF Frequency Generation and Pulse Programmer: Frequency range, 5 - 65 MHz (tested and validated on NMR frequencies as supplied by Bruker) with 1 Hz stepping, resolution better than 1 ppm. Pulse programmer, 20 ns timing resolution, virtually unlimited number of pulse generations. Phase resolution better than 0.2°
- Receiver/Analog Digital Converter (ADC): Digital quadrature receiver, variable gain and variable digital filter. Highly linear 14bit digitizer with up to 12.5 MHz digitization rate (dwell time 80 nanoseconds). 2 x 32k Number of complex data points.
- Broad Band Transmitter: Broad band transmitter with 7.5 MHz: 250 W; 10 MHz: 300 W; 20 MHz: 300 W; 40 MHz: 300 W; 60 MHz: 250 W output power.
- Software included: the minispec software for data acquisition for Microsoft Windows including daily check, update setting, status logging, autoprobe recognition of plug-and-play probes, and suitable minispec application pools, fitting to the proposed minispec hardware.
minispec mq20 magnet, 0.47 T, 20 MHz, 25 mm air gap, E1402220, consisting of:
- 20 MHz, 0.47 Tesla minispec magnet system with 25 mm air gap.
- Compatible with a wide range of 20 MHz probes for proton and flourine containing samples as well as for variable temperature and pulsed field gradients.
- magnet temperature control with digital PID control, pre-selection of magnet temperature (range 35 °C to 45 °C). Factory setting is 40 °C. Temperature stability better than 0.01 °C. Fast magnet pre-heat mode for rapid warm-up.
- EMI-shielded, CE-conform Housing with zero maintenance. Built-in sample storage compartment (up to 18 mm sample diameter) and LEDs for convenient diagnosis (on-temperature, connection).
- optical sample detector, based on optical technology for reliable and interference-free sample-in triggering and automatic launch of the minispec TD-NMR acquisition. Software configuration active/passive.
20 MHz Probe Assembly H20-10-25AVGX4 for mq20:
- 1H, suitable for sample tubes of 10 mm outer diameter
- compatible with magnet system with 25 mm air gap and 0.47 T magnetic field strength
- Absolute probe (long dead time, highest sensitivity): filling height 15 mm, 0.9 ml sample volume
- Operated with low power, so attenuation of