PFXi-950 + RCMSi Pack_1252125
Representative image only

PFXi-950 + RCMSi Pack

Bandwidth10 nm
Baseline CalibrationSingle key press; fully automated
Certified Reference Materials - AOCS-Tintometer® Colour 0.3R 2.0Y (5¼”)134240
Certified Reference Materials - AOCS-Tintometer® Colour 1.0R 9.0Y (5¼”)134250
Certified Reference Materials - AOCS-Tintometer® Colour 1.2R 12Y (5¼”)134260
Certified Reference Materials - AOCS-Tintometer® Colour 2.2R 22Y (5¼”)134270
Certified Reference Materials - ASTM Color < 0.5 500 ml134290
Certified Reference Materials - ASTM Color 1 500 ml134000
Certified Reference Materials - ASTM Color 3 500 ml134010
Certified Reference Materials - ASTM Color 5 500 ml134020
Certified Reference Materials - ASTM Color 7 500 ml134030
Certified Reference Materials - Gardner Colour 2134200
Certified Reference Materials - Gardner Colour 5134210
Certified Reference Materials - Gardner Colour 8134220
Certified Reference Materials - Lovibond® RYBN Colour 0.4R 1.9Y 0.1N (5¼”)134080
Certified Reference Materials - Lovibond® RYBN Colour 1.0R 4.3Y 0.1N (5¼”)134090
Certified Reference Materials - Lovibond® RYBN Colour 1.4R 7.3Y 0.2N (5¼”)134100
Certified Reference Materials - Lovibond® RYBN Colour 1.6R 11.0Y 0.1N (5¼”)134110
Certified Reference Materials - Lovibond® RYBN Colour 1.8R 14.0Y 0.3N (5¼”)134120
Certified Reference Materials - Lovibond® RYBN Colour 2.5R 24.0Y 0.5N (5¼”)134130
Certified Reference Materials - Platinum Cobalt Colour 0 (no certificate)133991
Certified Reference Materials - Platinum-Cobalt Colour 10134150
Certified Reference Materials - Platinum-Cobalt Colour 100134190
Certified Reference Materials - Platinum-Cobalt Colour 15134160
Certified Reference Materials - Platinum-Cobalt Colour 30134170
Certified Reference Materials - Platinum-Cobalt Colour 5134140
Certified Reference Materials - Platinum-Cobalt Colour 50134180
Certified Reference Materials - Platinum-Cobalt Colour 500462803
Certified Reference Materials - Saybolt Colour +12 500 ml134060
Certified Reference Materials - Saybolt Colour +25 500 ml134070
Certified Reference Materials - Saybolt Colour 0 500 ml134050
Certified Reference Materials - Saybolt Colour -10 500 ml134040
Colour Scale Upgrades - Acid Wash132110
Colour Scale Upgrades - AF960 scale extension139090
Colour Scale Upgrades - AOCS-Tintometer®132000
Colour Scale Upgrades - ASTM132060
Colour Scale Upgrades - Chlorophyll + beta Carotene138900
Colour Scale Upgrades - European Pharmacopoeia132080
Colour Scale Upgrades - Gardner132010
Colour Scale Upgrades - ICUMSA (420 & 560nm)132120
Colour Scale Upgrades - Iodine colour132040
Colour Scale Upgrades - IP units132140
Colour Scale Upgrades - Klett (blue filter KS-42)132050
Colour Scale Upgrades - Lovibond® RYBN132100
Colour Scale Upgrades - Pt-Co132030
Colour Scale Upgrades - Saybolt132070
Colour Scale Upgrades - US Pharmacopoeia132090
Colour Scale Upgrades - Yellowness Index132130
ComplianceCE, RoHS, WEEE
Conformance Filters - AOCS-Tintometer Filter Set - (3 filters: 0.5R 1.0Y, 3.7R 13.0Y, 6.6R 50Y)136900
Conformance Filters - ASTM Color Filter Set - (3 filters: 0.5, 3.5, 5.0)139510
Conformance Filters - Beta carotene - (1 filter: 45 ppm at 10 mm path length)139520
Conformance Filters - Chlorophyll A - (1 filter: 0.19 ppm at 10 mm path length)139530
Conformance Filters - FAC Colour Filter Set - (5 filters: 7, 13, 15, 29, 39)139700
Conformance Filters - Gardner Colour Filter Set - (4 filters: 2, 8, 12, 17)139560
Conformance Filters - IP Units Filter Set - (4 filters: 0.75, 1.25, 2.0, 3.5)137660
Conformance Filters - Klett (blue filter KS-42) Filter Set - (5 filters: 21, 66, 162, 318, 616)139710
Conformance Filters - Lovibond® Red, Yellow, Blue Filter Set - (5 filters)139620
Conformance Filters - Lovibond® Red, Yellow, Neutral Filter Set - (10 filters) - Sets 1 & 2139590
Conformance Filters - Lovibond® Red, Yellow, Neutral Filter Set - (5 filters) - Set 1139630
Conformance Filters - Lovibond® Red, Yellow, Neutral Filter Set - (5 filters) - Set 2139610
Conformance Filters - Pt-Co/Hazen/APHA Filter Set - (5 filters: 5, 20, 50, 100, 300)139570
Conformance Filters - Saybolt Colour Filter Set - (5 filters: -8, 0, +10, +18, +25)139580
Conformance Filters - Single Filter (Certificated) - (specify instrument, scale and nominal value from above)109970
Conformance Filters - User Specified Filter - (specify instrument, scale and value when ordering)109980
Data Storage100,000+ Measurements
DimensionsWidth 515, depth 196, height 170 (mm)
Display240 x 128, back-lit graphic display, (white on blue)
FAC132020
IlluminantsCIE Illuminant A, B, C, D65
Input VoltageUniversal (90 – 240 Vac), via external power supply
Instrument HousingFabricated steel with tough, textured paint finish
InterfacesUSB, LAN, RS232
Keypad23 key tactile membrane keypad; washable polyester with audible feedback
LanguagesEnglish, French, German, Italian, Portuguese, Russian, Spanish, Chinese and Japanese
Light Source5 Volt, 10 Watt Tungsten Halogen
Measurement TimeLess than 30 seconds
Measuring Principle16 interference filters
Observer2º, 10º
Path Length0.1 – 153 mm (0.004” – 6”)
Repeatability (Chromaticity (x y)/ΔE)On measurements of de-ionised water (+/– 0.0002/0.2)
Spectral Response420 – 710 nm
Weight7.7 kg
Overview

Oils, Chemicals & Derivatives
[Lovibond RYBN, AOCS-Tintometer Colour, Gardner Colour, CIE Values, Spectral Data]

-Integrated RCMSi Technology for Remote Calibration
-Automatic and non-subjective colour measurement
-Consistent data compliant with international standards
-Very rugged, chemically resistant, steel construction
-Easy maintenance with removable sample chamber
-Ability to handle hot samples with high melting points
-Extensive and flexible choice of colour scales
-Remote upgrade facility
-Calculation and description of "off-hue" status
-Supplied with colour control software for data analysis
-Conformance standard, cells and spare bulb included
-Output conforming to GLP including date, time, sample & user ID
-Accommodates a wide range of sample cells and tubes
-Extensive range of accessories (e.g. thermal printer)
-153mm (6") sample chamber guarantees compliance with AOCS, ISO and ASTM standards
-Optional integrated heater unit

Colour Scales and Values: AOCS-Tintometer® Colour, CIE L*a*b, Gardner Colour, xyY chromaticity co-ordinates, XYZ tristimulus values, Optical density (Absorbance), Lovibond® RYBN Colour, A Guide to Path Length by Colour Scale, Delta E* colour difference, Spectral data
Applications: Chemicals, Edible Oils & Fats

Over 40,000 Customers Trust John Morris