Intrinsically-safe, low profile industrial ICP® accel, 100 mV/g, 0.5 to 10k Hz, side exit, integral cable & swiveler base, single point ISO 17025 accredited calibration_1233795
Representative image only

Intrinsically-safe, low profile industrial ICP® accel, 100 mV/g, 0.5 to 10k Hz, side exit, integral cable & swiveler base, single point ISO 17025 accredited calibration

$1,073.60

The price is inclusive of GST
Drawing (PDF)
Product Manual (PDF)
Specifications (PDF)
Overview
Low profile industrial ICP® accelerometer, 100 mV/g, 0.5 to 10k Hz, side exit, 10-ft integral cable & swiveler base, single point ISO 17025 accredited calibration


Product Specifications
 ENGLISHSI 
Performance
    Sensitivity (±15 %)100 mV/g10.2 mV/(m/s²)[1] 
    Measurement Range±50 g±490 m/s² 
    Frequency Range (±3 dB)30 to 600000 cpm0.5 to 10000 Hz 
    Resonant Frequency1500 kcpm25 kHz[2] 
    Broadband Resolution (1)350 µg3434 µm/sec2[2] 
    Non-Linearity±1 %±1 %[3] 
    Transverse Sensitivity≤7 %≤7 % 
Environmental
    Overload Limit (Shock)5000 g pk49050 m/s² pk 
    Temperature Range-65 to +250 °F-54 to +121 °C 
    Enclosure RatingIP68IP68 
    Hazardous Area ApprovalEx ia IIC T4, AExia IIC, T4Ex ia IIC T4, AExia IIC, T4 
    Hazardous Area ApprovalEEx nL IIC T4, -40°C<><=121â°c, ii="" 1="">EEx nL IIC T4, -40°C<><=121â°c, ii="" 1=""> 
    Hazardous Area ApprovalCl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div ICl I, Div I, Groups A, B, C, D; Cl II, Div I, Groups E, F, G; Cl III, Div I 
    Hazardous Area ApprovalCl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4Cl I, Div 2, Groups A, B, C, D; ExnL IIC T4, AExnA IIC T4 
    Hazardous Area ApprovalEEx nL IIC T4, -40°C<><=121â°c, ii="" 3="">EEx nL IIC T4, -40°C<><=121â°c, ii="" 3=""> 
Electrical
    Settling Time (within 1% of bias)≤2 sec≤2 sec 
    Discharge Time Constant≥0.3 sec≥0.3 sec 
    Excitation Voltage18 to 28 VDC18 to 28 VDC 
    Constant Current Excitation2 to 20 mA2 to 20 mA 
    Output Impedance<150><150> 
    Output Bias Voltage8 to 12 VDC8 to 12 VDC 
    Spectral Noise (10 Hz)8 µg/√Hz78.5 (µm/sec2)/√Hz[2] 
    Spectral Noise (100 Hz)5 µg/√Hz49.1 (µm/sec2)/√Hz[2] 
    Spectral Noise (1 kHz)4 µg/√Hz39.2 (µm/sec2)/√Hz[2] 
    Electrical Isolation (Case)>100000000 Ohm>100000000 Ohm 
Physical
    Size - Hex9/16 in14 mm 
    Size - Height0.97 in24.6 mm 
    Weight (without cable)1.1 oz31 gm[4] 
    MountingStudStud 
    Mounting Thread1/4-28 Male1/4-28 Male[5] 
    Mounting Torque (stud)7 to 8 ft-lb9.5 to 10.8 Nm[7][8] 
    Mounting Torque (hex nut)2 to 5 ft-lb2.7 to 6.8 Nm 
    Sensing ElementCeramicCeramic 
    Sensing GeometryShearShear 
    Housing MaterialStainless SteelStainless Steel 
    SealingWelded HermeticWelded Hermetic 
    Electrical ConnectorMolded Integral CableMolded Integral Cable 
    Electrical Connection PositionSideSide 
    Cable Length10 ft3.0 m 
    Cable TypePolyurethanePolyurethane[6] 

All specifications are at room temperature unless otherwise specified.

CEceneleccsa_us
Product Notes
[1] Conversion Factor 1g = 9.81 m/s².
[2] Typical.
[3] Zero-based, least-squares, straight line method.
[4] Measured with mounting stud.
[5] 1/4-28 has no equivalent in S.I. units.
[6] Twisted shielded pair.
[7] 1/8" hex Allen key required for English version, 4 mm hex Allen key required for Metric version.
[8] Stud torque must exceed sensor hex nut torque to ensure proper dismantling.
[9] See PCB Declaration of Conformance PS023 or PS060 for details.