Model:121A44 - Intrinsic safe ICP® pressure sensor, 50 psi, 100 mV/psi, case isolated, 2-pin connector, temp to 250F_1112496
Representative image only

Model:121A44 - Intrinsic safe ICP® pressure sensor, 50 psi, 100 mV/psi, case isolated, 2-pin connector, temp to 250F

$6,339.30

The price is inclusive of GST
Drawing (PDF)
Product Manual (PDF)
Specifications (PDF)
Overview
Intrinsic safe ICP® pressure sensor, 50 psi, 100 mV/psi, case isolated, 2-pin connector, temp to 250F


Product Specifications
 ENGLISHSI 
Performance
    Measurement Range (for ±5V output)50 psi344.8 kPa 
    Sensitivity (±15 %)100 mV/psi14.5037 mV/kPa 
    Maximum Pressure8 kpsi55.16 MPa[2] 
    Resolution0.5 mpsi0.003 kPa 
    Resonant Frequency≥60 kHz≥60 kHz 
    Rise Time (Reflected)≤4 µ sec≤4 µ sec 
    Low Frequency Response (-5 %)0.5 Hz0.5 Hz 
    Non-Linearity≤2.0 % FS≤2.0 % FS[1] 
Environmental
    Acceleration Sensitivity≤0.05 psi/g≤0.035 kPa/(m/s²) 
    Temperature Range (Operating)-65 to +250 °F-54 to +121 °C 
    Hazardous Area ApprovalCSA (C-US) NRTL - Canadian Standards AssociationCSA (C-US) NRTL - Canadian Standards Association[3][4][5][6] 
    Hazardous Area ApprovalATEXATEX[7][8][9] 
Electrical
    Output Polarity (Positive Pressure)PositivePositive 
    Discharge Time Constant (at room temp)≥1.0 sec≥1.0 sec 
    Excitation Voltage22 to 28 VDC22 to 28 VDC 
    Constant Current Excitation2 to 20 mA2 to 20 mA 
    Output Impedance<100><100> 
    Output Bias Voltage10 to 15 VDC10 to 15 VDC 
    Electrical Isolation≥100000000 Ohm≥100000000 Ohm 
Physical
    Sensing GeometryCompressionCompression 
    Sensing ElementQuartzQuartz 
    Housing Material316L Stainless Steel316L Stainless Steel 
    Diaphragm316L Stainless Steel316L Stainless Steel 
    SealingWelded HermeticWelded Hermetic 
    Electrical Connector2-Pin MIL-C-50152-Pin MIL-C-5015 
    Weight2.7 oz75.6 gm 

All specifications are at room temperature unless otherwise specified.

CEceneleccsa_us
Product Notes
[1] Zero-based, least-squares, straight line method.
[2] Due to high sensitivity, the static pressure should be applied and removed very slowly. Rate should prevent more than 10 Volt change in output until Output Bias Voltage returns to normal (approximately 15 times discharge time constant).
[3] AEx ia IIC T4, DIV1 CL1 GR A-D
[4] Ex ia IIC T4, DIV1 CL1 GR A-D
[5] AEx nA IIC T4, DIV2 CL1 GR A-D
[6] Ex nL IIC T4, DIV2 CL1 GR A-D
[7] Ex ia IIC T4.
[8] Ex nL IIC T4.
[9] Ex nA IIC T4.
[10] See PCB Declaration of Conformance PS059 for details.
Accessories:
No Accessories
Optional Versions:
No optional versions