Cannon, Density/Specific Gravity Meter, D155, 9726-P10_1172071
Representative image only

Cannon, Density/Specific Gravity Meter, D155, 9726-P10

Data OutputRS-232C and USB
Dimensions (w × d × h)25.1 cm × 40.8 cm × 16.5 cm (10.0 in × 16.0 in × 6.5 in)
Electrical Specifications100 Vac to 240 Vac, 50/60 Hz; ~30 watts power consumption
Minimum sample volumeManual (syringe): 1 mL; With peristaltic pump: 8 mL
Operating conditions5 °C to 35 °C, <85% relative humidity (non-condensing)
RepeatabilityDensity (SD 0.0005 g/cm³)
ResolutionDensity (0.0001 g/cm³), Temperature (0.05 °C), Specific gravity (0.0001 step), Temperature compensated parameters (0.0001 step), API degree (0.1 step)
Temperature range and accuracy15 °C to 25 °C (0.1 °C step)
Test range and precisionDensity (0 g/cm³ to 2 g/cm³ ± 0.001 g/cm³)
Weight11.6 kg (25.6 lb)
CANNON D155 Flyer
Overview

The automated CANNON D155 offers a low-cost, affordable alternative to manual hydrometer methods for measuring density and specific gravity with easy, one button operation. D155 density meter has built-in thermal control provides quick, precise measurement with 4 decimal resolution.

Common Applications

  • Petrochemical (solvents, fuels, fuel oils, lubricants, crude oil)
  • Chemicals
  • Pharmaceuticals
  • Cosmetics
  • Food and beverages

Features & Benefits

Precision and accuracy in space-saving design

  • Compact and lightweight oscillation-type densitometer measures density, specific gravity and API degrees
  • Built-in, stable thermal control enables quick and precise density/specific gravity measurement with 4 decimal resolution
  • Meets requirements of ASTM D1250, ASTM D1298, ASTM D4052 and ASTM D77

Simple, automated operation

  • Easy, one button operation replace manual hydrometer methods and delivers results in approximately 2 to 4 minutes
  • Automates the entire testing process from sample injections (is using optional peristaltic pump), to temperature equilibrium to final density measurement
  • Introduction of the next sample flushes previous sample residual and eliminates the need for flushing solvents
  • Instrument is calibrated with pure water*

Versatile

  • Tests sample with maximum viscosities of ~1000 mPa·s (cSt)
  • Sampling performed manually by direct injection into the test cell or automatically via use of the optional peristaltic pump
  • Results may be output via the RS-232C port, stored on a USB storage device or printed to the optional DOT matrix printer
  • Internal memory retains results from the last 10 measurements

* Factory calibration is performed with air

Ordering

D155 Density/Specific Gravity Meter may be ordered with or without an optional peristaltic pump. Description  Part #
100 to 240 Vac, 50/60 Hz 9726-P10
100 to 240 Vac, 50/60 Hz with peristaltic pump 9726-P15

Over 40,000 Customers Trust John Morris