FLOWMETER MASS H2 500 SCCM_1138083
Representative image only

FLOWMETER MASS H2 500 SCCM

Accuracy±1.5% full-scale
CertifiedYes
DescriptionThermal Gas Mass Flowmeter, to 500 sccm H2, Aluminum body w/ display
Display Type3.5-digit LCD
Gas typeHydrogen
Height (Inch)5.375
Leak Integrity1 X 10-7 sccs He (max)
Length (Inch)1
Max flow rate (LPM)0.5
Max flow rate (SCCM)500
Max Operating Temperature (DegreeC)50
Max Operating Temperature (DegreeF)122
Max Particulate Size (microns)5
Max pressure (psi)1000
Media TypeHelium, Water, Argon, Air;Nitrogen, Oxygen, Air, Nitrogen, Acetylene;Air;Argon;Carbon Dioxide;Carbon Monoxide;Helium;Hydrogen;Nitrogen;Oxygen, Hydrogen
Min flow rate (LPM)0
Min Operating Temperature (DegreeC)0
Min Operating Temperature (DegreeF)32
OutputLinear 0 to 5 VDC (1000 Ω minimum load), 4 to 20 mA (50 to 250 Ω loop resistance)
Output (Voltage)Yes
Power12 VDC
Pressure drop at maximum flow (PSID)0.04
Process connection1/4" Compression Fittings
Repeatability±0.5% full-scale
Response Time (msec)2000
Wetted MaterialsAnodized Aluminum, Brass, Viton
Width (Inch)3
View Virtual Catalog - English - gy44-0370.pdf
Overview
  • Precisely measure flow rates and totals
  • Proven design uses metal body components for added durability
  • Accumulated flow can be logged using an optional totalizer
  • Includes NIST-traceable certificate

These flowmeters feature an advanced straight-tube sensor that ensures accurate and repeatable
results. Gas flow measurements are unaffected by moderate temperature and pressure variations
at the inlet. The meter also allows a four-point calibration across the flow range to improve meter
linearity. Output data from the meter can be sent via a 0 to 5 VDC or 4 to 20 mA signal; an analogto-
RS converter is available for data collection and analysis on your PC.

All meters include a detachable 3 1/2-digit LCD that can be tilted up to 90° for easy reading.
Remotely mount the display up to three feet using extension cable 32662-70. The optional totalizer
32650-22 displays accumulated flow. The meter is protected from polarity reversal or short circuit
by a built-in resettable fuse. Aluminum models have wetted materials of anodized aluminum,
brass, and Viton®; stainless steel (SS) models have wetted materials of SS and Viton.

Accuracy:
These precalibrated flow controllers operate at inlet pressures between 5 and 60 psi and at gas temperatures between 59 and 77°F (15 to 25°C) while maintaining the stated percent full-scale accuracy and linearity. When operating beyond 5 to 60 psi, add ±0.01%/psi full-scale; if operating beyond 59 to 77°F (15 to 25°C), add ±0.15%/°C full-scale.