Brand: Digi-Sense
JMG No: 1017171
Part No: 08466-82
UNSPSC: 41112206
Type: Instrument
Availability: Within 15 days
  • Insulated with FEP-Sealed Junction Used for Long-Term Immersion in Semi-Caustic Environments
  • Each Probe is hermetically sealed and tested to 25psi
  • Can be used for applications requiring an isolated junction.
  • Response Time: 0.75 seconds or greater
  • All insulated-wire probes include straight insulated cable with no handle and feature ANSI color-coded mini connectors: type J - black, type K - yellow, and type T - blue.
  • Custom designs or changes to this product are available upon request

Do not subject type J exposed-junction probes to moisture as they will rust

Connector Type Mini Connector
Junction Ungrounded
Probe type K
Sheath material FEP Insulated Wire
Temperature Accuracy ±3.0°F (1.1°C) or ±0.4% reading above 212°F(100°C); ±3.6°F (2.2°C) or 2% of reading between -58 to 211°F (-50 to 99°C); ±7.2°F (4°C) or ±4% of reading between -60 to -238 (-51 to -150°C), whichever is greater
Description Type-K, FEP-Insulated Probe, Coated Junct, Mini Conn, Ungrd, 10ft 24-Gauge
Length (Inch) 120
Max Temperature (DegreeC) 204
Min Temperature (DegreeF) -250
Min Temperature (DegreeC) -150
Cable Length (InchShort) 120
Max Temperature (DegreeF) 400
Cable Wire Gauge (Ga) 24
Sheath Length (InchShort) 120
I need to measure temperature evolution in concrete, from fresh (liquid state) concrete to hardened concrete, during one week. Can I use this probe?
Answer
Yes these probes would be suitable for measuring concrete.Answered on 2/19/2011 by David from Tech Support
Is the K-type FEP-insulated thermocouple probe with PTFE coated junction probe suitable for measuring the temperature of hot (~100degC) concentrated sulfuric acid solution?
Answer
Yes, the FEP and PTFE are chemically resistant to sulfuric, and should be fine even at increased temperatures (as long as they are within the overall temperature range of the probe).Answered on 10/23/2012 by Jen from Technical Support
Is this probe waterproof? If it is, can it be submerged in 190°F water?
Answer
This probe is suitable for long term immersion in hot water.Answered on 7/27/2010 by Jon from Technical Support
Would this probe be safe (food wise) to submerge in a grain/water mixture at temperatures ranging from 145-212 degrees for up to 90 minutes or longer?
Answer
This probe is good for long term immersion. The FEP coating is an FDA approved material for food contact. If 145 to 212 degrees F, yes that is fine. If you would be working in degrees C, please do not use this probe above 204 C.Answered on 7/3/2012 by Jen from Technical Support
OVERVIEW
SPECIFICATIONS
DOWNLOADS
Q&A
Brand: Digi-Sense
JMG No: 1017171
Part No: 08466-82
UNSPSC: 41112206
Type: Instrument
Availability: Within 15 days
  • Insulated with FEP-Sealed Junction Used for Long-Term Immersion in Semi-Caustic Environments
  • Each Probe is hermetically sealed and tested to 25psi
  • Can be used for applications requiring an isolated junction.
  • Response Time: 0.75 seconds or greater
  • All insulated-wire probes include straight insulated cable with no handle and feature ANSI color-coded mini connectors: type J - black, type K - yellow, and type T - blue.
  • Custom designs or changes to this product are available upon request

Do not subject type J exposed-junction probes to moisture as they will rust

Connector Type Mini Connector
Junction Ungrounded
Probe type K
Sheath material FEP Insulated Wire
Temperature Accuracy ±3.0°F (1.1°C) or ±0.4% reading above 212°F(100°C); ±3.6°F (2.2°C) or 2% of reading between -58 to 211°F (-50 to 99°C); ±7.2°F (4°C) or ±4% of reading between -60 to -238 (-51 to -150°C), whichever is greater
Description Type-K, FEP-Insulated Probe, Coated Junct, Mini Conn, Ungrd, 10ft 24-Gauge
Length (Inch) 120
Max Temperature (DegreeC) 204
Min Temperature (DegreeF) -250
Min Temperature (DegreeC) -150
Cable Length (InchShort) 120
Max Temperature (DegreeF) 400
Cable Wire Gauge (Ga) 24
Sheath Length (InchShort) 120
I need to measure temperature evolution in concrete, from fresh (liquid state) concrete to hardened concrete, during one week. Can I use this probe?
Answer
Yes these probes would be suitable for measuring concrete.Answered on 2/19/2011 by David from Tech Support
Is the K-type FEP-insulated thermocouple probe with PTFE coated junction probe suitable for measuring the temperature of hot (~100degC) concentrated sulfuric acid solution?
Answer
Yes, the FEP and PTFE are chemically resistant to sulfuric, and should be fine even at increased temperatures (as long as they are within the overall temperature range of the probe).Answered on 10/23/2012 by Jen from Technical Support
Is this probe waterproof? If it is, can it be submerged in 190°F water?
Answer
This probe is suitable for long term immersion in hot water.Answered on 7/27/2010 by Jon from Technical Support
Would this probe be safe (food wise) to submerge in a grain/water mixture at temperatures ranging from 145-212 degrees for up to 90 minutes or longer?
Answer
This probe is good for long term immersion. The FEP coating is an FDA approved material for food contact. If 145 to 212 degrees F, yes that is fine. If you would be working in degrees C, please do not use this probe above 204 C.Answered on 7/3/2012 by Jen from Technical Support
Customers Also Bought
Related Products
JMG Part No. 1227089
JMG Part No. 1252819

Digi-Sense Type-K, FEP-Insulated Probe, Coated Junct, Mini-Connector, Ungrounded, 10ft 24 -Gauge

OVERVIEW
SPECIFICATIONS
DOWNLOADS
Q&A
Brand: Digi-Sense
JMG No: 1017171
Part No: 08466-82
UNSPSC: 41112206
Type: Instrument
Availability: Within 15 days
  • Insulated with FEP-Sealed Junction Used for Long-Term Immersion in Semi-Caustic Environments
  • Each Probe is hermetically sealed and tested to 25psi
  • Can be used for applications requiring an isolated junction.
  • Response Time: 0.75 seconds or greater
  • All insulated-wire probes include straight insulated cable with no handle and feature ANSI color-coded mini connectors: type J - black, type K - yellow, and type T - blue.
  • Custom designs or changes to this product are available upon request

Do not subject type J exposed-junction probes to moisture as they will rust

Connector Type Mini Connector
Junction Ungrounded
Probe type K
Sheath material FEP Insulated Wire
Temperature Accuracy ±3.0°F (1.1°C) or ±0.4% reading above 212°F(100°C); ±3.6°F (2.2°C) or 2% of reading between -58 to 211°F (-50 to 99°C); ±7.2°F (4°C) or ±4% of reading between -60 to -238 (-51 to -150°C), whichever is greater
Description Type-K, FEP-Insulated Probe, Coated Junct, Mini Conn, Ungrd, 10ft 24-Gauge
Length (Inch) 120
Max Temperature (DegreeC) 204
Min Temperature (DegreeF) -250
Min Temperature (DegreeC) -150
Cable Length (InchShort) 120
Max Temperature (DegreeF) 400
Cable Wire Gauge (Ga) 24
Sheath Length (InchShort) 120
I need to measure temperature evolution in concrete, from fresh (liquid state) concrete to hardened concrete, during one week. Can I use this probe?
Answer
Yes these probes would be suitable for measuring concrete.Answered on 2/19/2011 by David from Tech Support
Is the K-type FEP-insulated thermocouple probe with PTFE coated junction probe suitable for measuring the temperature of hot (~100degC) concentrated sulfuric acid solution?
Answer
Yes, the FEP and PTFE are chemically resistant to sulfuric, and should be fine even at increased temperatures (as long as they are within the overall temperature range of the probe).Answered on 10/23/2012 by Jen from Technical Support
Is this probe waterproof? If it is, can it be submerged in 190°F water?
Answer
This probe is suitable for long term immersion in hot water.Answered on 7/27/2010 by Jon from Technical Support
Would this probe be safe (food wise) to submerge in a grain/water mixture at temperatures ranging from 145-212 degrees for up to 90 minutes or longer?
Answer
This probe is good for long term immersion. The FEP coating is an FDA approved material for food contact. If 145 to 212 degrees F, yes that is fine. If you would be working in degrees C, please do not use this probe above 204 C.Answered on 7/3/2012 by Jen from Technical Support
OVERVIEW
SPECIFICATIONS
DOWNLOADS
Q&A
Brand: Digi-Sense
JMG No: 1017171
Part No: 08466-82
UNSPSC: 41112206
Type: Instrument
Availability: Within 15 days
  • Insulated with FEP-Sealed Junction Used for Long-Term Immersion in Semi-Caustic Environments
  • Each Probe is hermetically sealed and tested to 25psi
  • Can be used for applications requiring an isolated junction.
  • Response Time: 0.75 seconds or greater
  • All insulated-wire probes include straight insulated cable with no handle and feature ANSI color-coded mini connectors: type J - black, type K - yellow, and type T - blue.
  • Custom designs or changes to this product are available upon request

Do not subject type J exposed-junction probes to moisture as they will rust

Connector Type Mini Connector
Junction Ungrounded
Probe type K
Sheath material FEP Insulated Wire
Temperature Accuracy ±3.0°F (1.1°C) or ±0.4% reading above 212°F(100°C); ±3.6°F (2.2°C) or 2% of reading between -58 to 211°F (-50 to 99°C); ±7.2°F (4°C) or ±4% of reading between -60 to -238 (-51 to -150°C), whichever is greater
Description Type-K, FEP-Insulated Probe, Coated Junct, Mini Conn, Ungrd, 10ft 24-Gauge
Length (Inch) 120
Max Temperature (DegreeC) 204
Min Temperature (DegreeF) -250
Min Temperature (DegreeC) -150
Cable Length (InchShort) 120
Max Temperature (DegreeF) 400
Cable Wire Gauge (Ga) 24
Sheath Length (InchShort) 120
I need to measure temperature evolution in concrete, from fresh (liquid state) concrete to hardened concrete, during one week. Can I use this probe?
Answer
Yes these probes would be suitable for measuring concrete.Answered on 2/19/2011 by David from Tech Support
Is the K-type FEP-insulated thermocouple probe with PTFE coated junction probe suitable for measuring the temperature of hot (~100degC) concentrated sulfuric acid solution?
Answer
Yes, the FEP and PTFE are chemically resistant to sulfuric, and should be fine even at increased temperatures (as long as they are within the overall temperature range of the probe).Answered on 10/23/2012 by Jen from Technical Support
Is this probe waterproof? If it is, can it be submerged in 190°F water?
Answer
This probe is suitable for long term immersion in hot water.Answered on 7/27/2010 by Jon from Technical Support
Would this probe be safe (food wise) to submerge in a grain/water mixture at temperatures ranging from 145-212 degrees for up to 90 minutes or longer?
Answer
This probe is good for long term immersion. The FEP coating is an FDA approved material for food contact. If 145 to 212 degrees F, yes that is fine. If you would be working in degrees C, please do not use this probe above 204 C.Answered on 7/3/2012 by Jen from Technical Support