$7208 AUD (Ex. GST)
Qty:
Enquiry sent successfully
Product Enquiry
OVERVIEW
SPECIFICATIONS
DOWNLOADS
Brand: Binder
JMG No: 1242308
Part No: 9010-0309
Type: Instrument
Availability: Within 71 days

Important characteristics

  • Temperature range (model 56; model 260): ambient temperature plus 5 °C to 300 °C
  • Temperature range (model 115): ambient temperature plus 6 °C to 300 °C
  • High temperature accuracy thanks to APT.line™ technology
  • Natural convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Units up to 115 L are stackable
  • Class 2 independent temperature safety device (DIN 12880) with visual temperature alarm
  • Ergonomic handle design
  • USB port for recording data


Options:
 

Designation Description Art. No.
 
Access port with silicone plug

top

100 mm
8012-1671

top

50 mm
8012-1380

top

30 mm
8012-1364

left

10 mm
8012-1276

right

10 mm
8012-1269

top

10 mm
8012-1263

left

50 mm
8012-1020

right

50 mm
8012-1019

left

30 mm
8012-1016

right

30 mm
8012-1015

right

100 mm
8012-1028

left

100 mm
8012-1027
Analog output 4-20 mA

for temperature values (output not adjustable)

8012-1624
Calibration certificate, expanded

for temperature; for extending the measurement in center of chamber to include another test temperature

8012-1116
Calibration certificate, temperature

temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1594

temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1573

temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1552

for temperature, measurement in center of chamber at specified temperature

8012-1135
Cart

Cart – stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm

9051-0019
Class 3.1 independent temperature safety device

with visual alarm (DIN 12880)

8012-1643
Clock

battery-backed

8012-1641
Data Logger Kit

T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit

8012-0714
Data Logger Software

LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable)

8012-0821
Door gasket

made of FKM, silicone-free

8012-1652
Door lock

lockable door handle

8012-1665
Ethernet interface

for communication software

8012-0988
Gas-tight option model

Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-1687
HEPA air filter

On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm)

8012-1052
Inert gas connection

With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-1693
Inner chamber, reinforced

max. total load 300 kg

8012-1055
Instrument tray

with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm

large
4022-0124

with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm

small
4022-0123
Interior lighting

with 15 W light bulb

230/240 V option model
8012-1628
Load management

to comply with EMC requirements in accordance with EN 61326-1:2013-07 (IEC 61326-1:2012)

8012-1646
Measurement of air exchange rate

in accordance with ASTM D5374, definition and protocol according to ambient temperature

8012-1195
Overheating alarm

audible, can be switched off, adjustable limit on the independent temperature safety device

8012-1636
pH-neutral detergent

concentrated, for gentle remove of residual contaminants; 1 kg

1002-0016
Pt 100 temperature sensor

additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-1620
Rack, heavy load

Stainless steel, max. load per rack 70 kg

6004-0200
Racks

chrome-plated

6004-0169

stainless steel

6004-0153
Rubber pads

set of 4 anti-slip feet, for safe stacking of unit

8012-0001
Shelf, perforated
Stainless steel
6004-0185
Software

APT-COM™ communications software

version 2 to 3, GLP edition
9053-0016

APT-COM™ communications software

version 3, GLP edition
9053-0015

APT-COM™ communications software

version 3, BASIC edition
9053-0014

APT-COM™ communications software

version 3, STANDARD edition
9053-0013

APT-COM™ communications software, price: for free

version 3, GLP DEMO Edition
9053-0008
Viewing window and interior lighting

viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior

240 V option model
8012-1710

viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior

230 V option model
8012-1708
 
Option model Standard
Performance Data Temperature: Temperature range 10 °C above ambient temperature to [°C] 300
Performance Data Temperature: Temperature variation at 150 °C [± K] 1.9
Performance Data Temperature: Temperature fluctuation at 150 °C [± K] 0.5
Performance Data Temperature: Heating-up time to 150 °C [min] 20
Performance Data Temperature: Recovery time after 30 seconds door open at 150 °C [min] 6
Electrical data: Rated Voltage [V] 230
Electrical data: Power frequency [Hz] 50/60
Electrical data: Nominal power [kW] 2.3
Electrical data: Unit fuse [A] 12.5
Electrical data: Phase (Nominal voltage) [ph] 1
Measures: Interior volume [L] 259
Measures: Net weight of the unit (empty) [kg] 85
Measures: permitted load [kg] 270
Measures: Load per rack [kg] 40
Measures - Doors: Unit doors 1
Measures - Internal Dimensions: Width [mm] 650
Measures - Internal Dimensions: Height [mm] 780
Measures - Internal Dimensions: Depth [mm] 515
Measures - Outer dimensions: Width net [mm] 810
Measures - Outer dimensions: Height net [mm] 965
Measures - Outer dimensions: Depth net [mm] 760
Measures - Outer dimensions: Wall clearance back [mm] 100
Measures - Outer dimensions: Wall clearance sidewise [mm] 100
Environment-specific data: Energy consumption at 150 °C 420 Wh/h
Environment-specific data: Sound-pressure level [dB(A)] 43
Fixtures: Number of shelves (std./max.) 2/8
OVERVIEW
SPECIFICATIONS
DOWNLOADS
Brand: Binder
JMG No: 1242308
Part No: 9010-0309
Type: Instrument
Availability: Within 71 days

Important characteristics

  • Temperature range (model 56; model 260): ambient temperature plus 5 °C to 300 °C
  • Temperature range (model 115): ambient temperature plus 6 °C to 300 °C
  • High temperature accuracy thanks to APT.line™ technology
  • Natural convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Units up to 115 L are stackable
  • Class 2 independent temperature safety device (DIN 12880) with visual temperature alarm
  • Ergonomic handle design
  • USB port for recording data


Options:
 

Designation Description Art. No.
 
Access port with silicone plug

top

100 mm
8012-1671

top

50 mm
8012-1380

top

30 mm
8012-1364

left

10 mm
8012-1276

right

10 mm
8012-1269

top

10 mm
8012-1263

left

50 mm
8012-1020

right

50 mm
8012-1019

left

30 mm
8012-1016

right

30 mm
8012-1015

right

100 mm
8012-1028

left

100 mm
8012-1027
Analog output 4-20 mA

for temperature values (output not adjustable)

8012-1624
Calibration certificate, expanded

for temperature; for extending the measurement in center of chamber to include another test temperature

8012-1116
Calibration certificate, temperature

temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1594

temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1573

temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1552

for temperature, measurement in center of chamber at specified temperature

8012-1135
Cart

Cart – stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm

9051-0019
Class 3.1 independent temperature safety device

with visual alarm (DIN 12880)

8012-1643
Clock

battery-backed

8012-1641
Data Logger Kit

T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit

8012-0714
Data Logger Software

LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable)

8012-0821
Door gasket

made of FKM, silicone-free

8012-1652
Door lock

lockable door handle

8012-1665
Ethernet interface

for communication software

8012-0988
Gas-tight option model

Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-1687
HEPA air filter

On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm)

8012-1052
Inert gas connection

With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-1693
Inner chamber, reinforced

max. total load 300 kg

8012-1055
Instrument tray

with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm

large
4022-0124

with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm

small
4022-0123
Interior lighting

with 15 W light bulb

230/240 V option model
8012-1628
Load management

to comply with EMC requirements in accordance with EN 61326-1:2013-07 (IEC 61326-1:2012)

8012-1646
Measurement of air exchange rate

in accordance with ASTM D5374, definition and protocol according to ambient temperature

8012-1195
Overheating alarm

audible, can be switched off, adjustable limit on the independent temperature safety device

8012-1636
pH-neutral detergent

concentrated, for gentle remove of residual contaminants; 1 kg

1002-0016
Pt 100 temperature sensor

additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-1620
Rack, heavy load

Stainless steel, max. load per rack 70 kg

6004-0200
Racks

chrome-plated

6004-0169

stainless steel

6004-0153
Rubber pads

set of 4 anti-slip feet, for safe stacking of unit

8012-0001
Shelf, perforated
Stainless steel
6004-0185
Software

APT-COM™ communications software

version 2 to 3, GLP edition
9053-0016

APT-COM™ communications software

version 3, GLP edition
9053-0015

APT-COM™ communications software

version 3, BASIC edition
9053-0014

APT-COM™ communications software

version 3, STANDARD edition
9053-0013

APT-COM™ communications software, price: for free

version 3, GLP DEMO Edition
9053-0008
Viewing window and interior lighting

viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior

240 V option model
8012-1710

viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior

230 V option model
8012-1708
 
Option model Standard
Performance Data Temperature: Temperature range 10 °C above ambient temperature to [°C] 300
Performance Data Temperature: Temperature variation at 150 °C [± K] 1.9
Performance Data Temperature: Temperature fluctuation at 150 °C [± K] 0.5
Performance Data Temperature: Heating-up time to 150 °C [min] 20
Performance Data Temperature: Recovery time after 30 seconds door open at 150 °C [min] 6
Electrical data: Rated Voltage [V] 230
Electrical data: Power frequency [Hz] 50/60
Electrical data: Nominal power [kW] 2.3
Electrical data: Unit fuse [A] 12.5
Electrical data: Phase (Nominal voltage) [ph] 1
Measures: Interior volume [L] 259
Measures: Net weight of the unit (empty) [kg] 85
Measures: permitted load [kg] 270
Measures: Load per rack [kg] 40
Measures - Doors: Unit doors 1
Measures - Internal Dimensions: Width [mm] 650
Measures - Internal Dimensions: Height [mm] 780
Measures - Internal Dimensions: Depth [mm] 515
Measures - Outer dimensions: Width net [mm] 810
Measures - Outer dimensions: Height net [mm] 965
Measures - Outer dimensions: Depth net [mm] 760
Measures - Outer dimensions: Wall clearance back [mm] 100
Measures - Outer dimensions: Wall clearance sidewise [mm] 100
Environment-specific data: Energy consumption at 150 °C 420 Wh/h
Environment-specific data: Sound-pressure level [dB(A)] 43
Fixtures: Number of shelves (std./max.) 2/8
Customers Also Bought
$573 (Ex. GST)
JMG Part No. 1242767
$465 (Ex. GST)
JMG Part No. 1242711
$573 (Ex. GST)
JMG Part No. 1242705
JMG Part No. 1242430
JMG Part No. 1242307

Model FD 260 - Drying and heating chambers Avantgarde.Line with forced convection

OVERVIEW
SPECIFICATIONS
DOWNLOADS
Brand: Binder
JMG No: 1242308
Part No: 9010-0309
Type: Instrument
Availability: Within 71 days

Important characteristics

  • Temperature range (model 56; model 260): ambient temperature plus 5 °C to 300 °C
  • Temperature range (model 115): ambient temperature plus 6 °C to 300 °C
  • High temperature accuracy thanks to APT.line™ technology
  • Natural convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Units up to 115 L are stackable
  • Class 2 independent temperature safety device (DIN 12880) with visual temperature alarm
  • Ergonomic handle design
  • USB port for recording data


Options:
 

Designation Description Art. No.
 
Access port with silicone plug

top

100 mm
8012-1671

top

50 mm
8012-1380

top

30 mm
8012-1364

left

10 mm
8012-1276

right

10 mm
8012-1269

top

10 mm
8012-1263

left

50 mm
8012-1020

right

50 mm
8012-1019

left

30 mm
8012-1016

right

30 mm
8012-1015

right

100 mm
8012-1028

left

100 mm
8012-1027
Analog output 4-20 mA

for temperature values (output not adjustable)

8012-1624
Calibration certificate, expanded

for temperature; for extending the measurement in center of chamber to include another test temperature

8012-1116
Calibration certificate, temperature

temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1594

temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1573

temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1552

for temperature, measurement in center of chamber at specified temperature

8012-1135
Cart

Cart – stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm

9051-0019
Class 3.1 independent temperature safety device

with visual alarm (DIN 12880)

8012-1643
Clock

battery-backed

8012-1641
Data Logger Kit

T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit

8012-0714
Data Logger Software

LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable)

8012-0821
Door gasket

made of FKM, silicone-free

8012-1652
Door lock

lockable door handle

8012-1665
Ethernet interface

for communication software

8012-0988
Gas-tight option model

Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-1687
HEPA air filter

On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm)

8012-1052
Inert gas connection

With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-1693
Inner chamber, reinforced

max. total load 300 kg

8012-1055
Instrument tray

with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm

large
4022-0124

with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm

small
4022-0123
Interior lighting

with 15 W light bulb

230/240 V option model
8012-1628
Load management

to comply with EMC requirements in accordance with EN 61326-1:2013-07 (IEC 61326-1:2012)

8012-1646
Measurement of air exchange rate

in accordance with ASTM D5374, definition and protocol according to ambient temperature

8012-1195
Overheating alarm

audible, can be switched off, adjustable limit on the independent temperature safety device

8012-1636
pH-neutral detergent

concentrated, for gentle remove of residual contaminants; 1 kg

1002-0016
Pt 100 temperature sensor

additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-1620
Rack, heavy load

Stainless steel, max. load per rack 70 kg

6004-0200
Racks

chrome-plated

6004-0169

stainless steel

6004-0153
Rubber pads

set of 4 anti-slip feet, for safe stacking of unit

8012-0001
Shelf, perforated
Stainless steel
6004-0185
Software

APT-COM™ communications software

version 2 to 3, GLP edition
9053-0016

APT-COM™ communications software

version 3, GLP edition
9053-0015

APT-COM™ communications software

version 3, BASIC edition
9053-0014

APT-COM™ communications software

version 3, STANDARD edition
9053-0013

APT-COM™ communications software, price: for free

version 3, GLP DEMO Edition
9053-0008
Viewing window and interior lighting

viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior

240 V option model
8012-1710

viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior

230 V option model
8012-1708
 
Option model Standard
Performance Data Temperature: Temperature range 10 °C above ambient temperature to [°C] 300
Performance Data Temperature: Temperature variation at 150 °C [± K] 1.9
Performance Data Temperature: Temperature fluctuation at 150 °C [± K] 0.5
Performance Data Temperature: Heating-up time to 150 °C [min] 20
Performance Data Temperature: Recovery time after 30 seconds door open at 150 °C [min] 6
Electrical data: Rated Voltage [V] 230
Electrical data: Power frequency [Hz] 50/60
Electrical data: Nominal power [kW] 2.3
Electrical data: Unit fuse [A] 12.5
Electrical data: Phase (Nominal voltage) [ph] 1
Measures: Interior volume [L] 259
Measures: Net weight of the unit (empty) [kg] 85
Measures: permitted load [kg] 270
Measures: Load per rack [kg] 40
Measures - Doors: Unit doors 1
Measures - Internal Dimensions: Width [mm] 650
Measures - Internal Dimensions: Height [mm] 780
Measures - Internal Dimensions: Depth [mm] 515
Measures - Outer dimensions: Width net [mm] 810
Measures - Outer dimensions: Height net [mm] 965
Measures - Outer dimensions: Depth net [mm] 760
Measures - Outer dimensions: Wall clearance back [mm] 100
Measures - Outer dimensions: Wall clearance sidewise [mm] 100
Environment-specific data: Energy consumption at 150 °C 420 Wh/h
Environment-specific data: Sound-pressure level [dB(A)] 43
Fixtures: Number of shelves (std./max.) 2/8
OVERVIEW
SPECIFICATIONS
DOWNLOADS
Brand: Binder
JMG No: 1242308
Part No: 9010-0309
Type: Instrument
Availability: Within 71 days

Important characteristics

  • Temperature range (model 56; model 260): ambient temperature plus 5 °C to 300 °C
  • Temperature range (model 115): ambient temperature plus 6 °C to 300 °C
  • High temperature accuracy thanks to APT.line™ technology
  • Natural convection
  • Controller with LCD display
  • Electromechanical control of the exhaust air flap
  • 2 chrome-plated racks
  • Units up to 115 L are stackable
  • Class 2 independent temperature safety device (DIN 12880) with visual temperature alarm
  • Ergonomic handle design
  • USB port for recording data


Options:
 

Designation Description Art. No.
 
Access port with silicone plug

top

100 mm
8012-1671

top

50 mm
8012-1380

top

30 mm
8012-1364

left

10 mm
8012-1276

right

10 mm
8012-1269

top

10 mm
8012-1263

left

50 mm
8012-1020

right

50 mm
8012-1019

left

30 mm
8012-1016

right

30 mm
8012-1015

right

100 mm
8012-1028

left

100 mm
8012-1027
Analog output 4-20 mA

for temperature values (output not adjustable)

8012-1624
Calibration certificate, expanded

for temperature; for extending the measurement in center of chamber to include another test temperature

8012-1116
Calibration certificate, temperature

temperature measurement incl. certificate and 27 measuring points at specified temperature

8012-1594

temperature measurement incl. certificate, 15- 18 measuring points at specified temperature

8012-1573

temperature measurement incl. certificate, 9 measuring points at specified temperature

8012-1552

for temperature, measurement in center of chamber at specified temperature

8012-1135
Cart

Cart – stable cart, casters with locking brakes, dimensions: W 1,300 x D 800 x H 780 mm

9051-0019
Class 3.1 independent temperature safety device

with visual alarm (DIN 12880)

8012-1643
Clock

battery-backed

8012-1641
Data Logger Kit

T 350: For continuous temperature logging from 0 °C to 350 °C; kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit

8012-0714
Data Logger Software

LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable)

8012-0821
Door gasket

made of FKM, silicone-free

8012-1652
Door lock

lockable door handle

8012-1665
Ethernet interface

for communication software

8012-0988
Gas-tight option model

Incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-1687
HEPA air filter

On fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995% at 0.3 µm)

8012-1052
Inert gas connection

With gas inlet and outlet, Ø 10 mm, incl. additional measures for the greatest possible impermeability to gas; not in conjunction with access port or interior lighting option

8012-1693
Inner chamber, reinforced

max. total load 300 kg

8012-1055
Instrument tray

with lid made from 18/8 stainless steel, stackable, dimensions: 315 x 215 x 60 mm

large
4022-0124

with lid made from 18/8 stainless steel, stackable, dimensions: 230 x 133 x 45 mm

small
4022-0123
Interior lighting

with 15 W light bulb

230/240 V option model
8012-1628
Load management

to comply with EMC requirements in accordance with EN 61326-1:2013-07 (IEC 61326-1:2012)

8012-1646
Measurement of air exchange rate

in accordance with ASTM D5374, definition and protocol according to ambient temperature

8012-1195
Overheating alarm

audible, can be switched off, adjustable limit on the independent temperature safety device

8012-1636
pH-neutral detergent

concentrated, for gentle remove of residual contaminants; 1 kg

1002-0016
Pt 100 temperature sensor

additional flexible Pt 100, interior, for displaying the temperature on the unit display

8012-1620
Rack, heavy load

Stainless steel, max. load per rack 70 kg

6004-0200
Racks

chrome-plated

6004-0169

stainless steel

6004-0153
Rubber pads

set of 4 anti-slip feet, for safe stacking of unit

8012-0001
Shelf, perforated
Stainless steel
6004-0185
Software

APT-COM™ communications software

version 2 to 3, GLP edition
9053-0016

APT-COM™ communications software

version 3, GLP edition
9053-0015

APT-COM™ communications software

version 3, BASIC edition
9053-0014

APT-COM™ communications software

version 3, STANDARD edition
9053-0013

APT-COM™ communications software, price: for free

version 3, GLP DEMO Edition
9053-0008
Viewing window and interior lighting

viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior

240 V option model
8012-1710

viewing window (triple insulating glass) in door, 370 x 370 mm, and 15 W interior

230 V option model
8012-1708
 
Option model Standard
Performance Data Temperature: Temperature range 10 °C above ambient temperature to [°C] 300
Performance Data Temperature: Temperature variation at 150 °C [± K] 1.9
Performance Data Temperature: Temperature fluctuation at 150 °C [± K] 0.5
Performance Data Temperature: Heating-up time to 150 °C [min] 20
Performance Data Temperature: Recovery time after 30 seconds door open at 150 °C [min] 6
Electrical data: Rated Voltage [V] 230
Electrical data: Power frequency [Hz] 50/60
Electrical data: Nominal power [kW] 2.3
Electrical data: Unit fuse [A] 12.5
Electrical data: Phase (Nominal voltage) [ph] 1
Measures: Interior volume [L] 259
Measures: Net weight of the unit (empty) [kg] 85
Measures: permitted load [kg] 270
Measures: Load per rack [kg] 40
Measures - Doors: Unit doors 1
Measures - Internal Dimensions: Width [mm] 650
Measures - Internal Dimensions: Height [mm] 780
Measures - Internal Dimensions: Depth [mm] 515
Measures - Outer dimensions: Width net [mm] 810
Measures - Outer dimensions: Height net [mm] 965
Measures - Outer dimensions: Depth net [mm] 760
Measures - Outer dimensions: Wall clearance back [mm] 100
Measures - Outer dimensions: Wall clearance sidewise [mm] 100
Environment-specific data: Energy consumption at 150 °C 420 Wh/h
Environment-specific data: Sound-pressure level [dB(A)] 43
Fixtures: Number of shelves (std./max.) 2/8
$7208 AUD (Ex. GST)