$344 AUD (Ex. GST)
Qty:
Enquiry sent successfully
Product Enquiry
OVERVIEW
SPECIFICATIONS
Brand: Gilson
JMG No: 1152006
Part No: F123601
Type: Instrument
Availability: In Stock

PIPETMAN Classic™: The Incarnation of Gilson's Reliability, the World Pipetting Standard!

The Pipetting Standard - Gilson's PIPETMAN Classic is designed and manufactured to provide you with a range of robust, accurate and precise pipettes. The PIPETMAN Classic is a fully adjustable, air-displacement pipette with the selected volume shown on a digital indicator (volumeter).

Your Benefits
Premium Robustness

  • Long product life and high resistance to agressive chemicals thanks to its stainless-steel and PVDF components.
  • Air-tight seal with unique "dry seal" technology (grease-free).

Accuracy & Precision

  • Performance exceeding ISO recommendations by an average of 50%.
  • PIPETMAN P5000 and PIPETMAN P10ml are safer and more accurate than glass pipettes.

Applications

  • PIPETMAN P2 and P10 models are ideal for molecular biology techniques (PCR, DNA sequencing, etc).
  • PIPETMAN P20, P100, P200, and P1000 models are suited for small-volume dispensing of aqueous fluids of moderate viscosity and density (molecular biology, immunology, etc).
  • PIPETMAN P5000 and P10ml models are ideal for large-volume dispensing of aqueous fluids of moderate viscosity and density.

More About the Features

  • Tip-holder and tip-ejector are fully autoclavable to avoid cross-contamination.
  • P2 and P10 are equipped with a dual position tip ejector allowing the use of PIPETMAN DIAMOND D10 (short tip) and DL10 (long tip).
  • PIPETMAN P5000 and P10ml are equipped with a polyethylene filter that prolongs piston life and prevents contamination.

Reliability
Gilson's standards are even more stringent than those required by governing bodies: On average, PIPETMAN permissible errors are 2 times better than those recommended by ISO 8655!

Our pipette manufacturing plant has its own accredited calibration laboratory to control the accuracy and precision of each and every Gilson pipette. Gilson pipettes are individually calibrated and delivered with a performance check report. Each pipette bears an engraved identification number for traceability.

Decontamination & Autoclaving
Your pipette could be contaminated accidentally. The most frequently contaminated pipette parts are the tip-ejector and tip-holder.

For this reason, each and every Gilson PIPETMAN has autoclavable lower parts.

Autoclaving
Tip-ejector, tip-holder and connecting nut can be sterilised in the laboratory under the following conditions: Moist heat/121°C/20 minutes/1 bar.

Decontamination
For maintenance and decontamination procedures, please refer to the related PIPETMAN user's guide.

Service
Gilson believe that the quality of their pipettes must be matched by the quality of their service. That is why John Morris Scientific operate a Gilson-authorised service centre. This repair and calibration centre duplicates the conditions of Gilson's own factory, with controlled environments and regular inspections. Qualified technicians at our centre, having completed extensive training by Gilson, are specialists in the repair, calibration, and operation of Gilson products.

Compliance with Standards
ISO standards and Good Laboratory Practice (GLP) require that laboratories perform regular inspections and calibration certification. Whatever your requirements - ISO standards, GLP guidelines, metrology - our specialists can help you implement procedures that are suitable for your applications.

 

 

 

 

 

 

 

 

 


 

Minimal Volume 20µl
Nominal Volume 200µl
ISO-8655 Permissible Errors, Systematic Error ±1.60µl
ISO-8655 Permissible Errors, Random Error ≤0.60µl
Gilson Maximum Permissible Errors, Systematic Error, at 200µl volume ±1.60µl
Gilson Maximum Permissible Errors, Random Error, at 200µl volume ≤0.30µl
Gilson Maximum Permissible Errors, Systematic Error, at 100µl volume ±0.80µl
Gilson Maximum Permissible Errors, Systematic Error, at 50µl volume ±0.50µl
Gilson Maximum Permissible Errors, Random Error, at 100µl volume ≤0.25µl
Gilson Maximum Permissible Errors, Random Error, at 50µl volume ≤0.20µl
    OVERVIEW
    SPECIFICATIONS
    Brand: Gilson
    JMG No: 1152006
    Part No: F123601
    Type: Instrument
    Availability: In Stock

    PIPETMAN Classic™: The Incarnation of Gilson's Reliability, the World Pipetting Standard!

    The Pipetting Standard - Gilson's PIPETMAN Classic is designed and manufactured to provide you with a range of robust, accurate and precise pipettes. The PIPETMAN Classic is a fully adjustable, air-displacement pipette with the selected volume shown on a digital indicator (volumeter).

    Your Benefits
    Premium Robustness

    • Long product life and high resistance to agressive chemicals thanks to its stainless-steel and PVDF components.
    • Air-tight seal with unique "dry seal" technology (grease-free).

    Accuracy & Precision

    • Performance exceeding ISO recommendations by an average of 50%.
    • PIPETMAN P5000 and PIPETMAN P10ml are safer and more accurate than glass pipettes.

    Applications

    • PIPETMAN P2 and P10 models are ideal for molecular biology techniques (PCR, DNA sequencing, etc).
    • PIPETMAN P20, P100, P200, and P1000 models are suited for small-volume dispensing of aqueous fluids of moderate viscosity and density (molecular biology, immunology, etc).
    • PIPETMAN P5000 and P10ml models are ideal for large-volume dispensing of aqueous fluids of moderate viscosity and density.

    More About the Features

    • Tip-holder and tip-ejector are fully autoclavable to avoid cross-contamination.
    • P2 and P10 are equipped with a dual position tip ejector allowing the use of PIPETMAN DIAMOND D10 (short tip) and DL10 (long tip).
    • PIPETMAN P5000 and P10ml are equipped with a polyethylene filter that prolongs piston life and prevents contamination.

    Reliability
    Gilson's standards are even more stringent than those required by governing bodies: On average, PIPETMAN permissible errors are 2 times better than those recommended by ISO 8655!

    Our pipette manufacturing plant has its own accredited calibration laboratory to control the accuracy and precision of each and every Gilson pipette. Gilson pipettes are individually calibrated and delivered with a performance check report. Each pipette bears an engraved identification number for traceability.

    Decontamination & Autoclaving
    Your pipette could be contaminated accidentally. The most frequently contaminated pipette parts are the tip-ejector and tip-holder.

    For this reason, each and every Gilson PIPETMAN has autoclavable lower parts.

    Autoclaving
    Tip-ejector, tip-holder and connecting nut can be sterilised in the laboratory under the following conditions: Moist heat/121°C/20 minutes/1 bar.

    Decontamination
    For maintenance and decontamination procedures, please refer to the related PIPETMAN user's guide.

    Service
    Gilson believe that the quality of their pipettes must be matched by the quality of their service. That is why John Morris Scientific operate a Gilson-authorised service centre. This repair and calibration centre duplicates the conditions of Gilson's own factory, with controlled environments and regular inspections. Qualified technicians at our centre, having completed extensive training by Gilson, are specialists in the repair, calibration, and operation of Gilson products.

    Compliance with Standards
    ISO standards and Good Laboratory Practice (GLP) require that laboratories perform regular inspections and calibration certification. Whatever your requirements - ISO standards, GLP guidelines, metrology - our specialists can help you implement procedures that are suitable for your applications.

     

     

     

     

     

     

     

     

     


     

    Minimal Volume 20µl
    Nominal Volume 200µl
    ISO-8655 Permissible Errors, Systematic Error ±1.60µl
    ISO-8655 Permissible Errors, Random Error ≤0.60µl
    Gilson Maximum Permissible Errors, Systematic Error, at 200µl volume ±1.60µl
    Gilson Maximum Permissible Errors, Random Error, at 200µl volume ≤0.30µl
    Gilson Maximum Permissible Errors, Systematic Error, at 100µl volume ±0.80µl
    Gilson Maximum Permissible Errors, Systematic Error, at 50µl volume ±0.50µl
    Gilson Maximum Permissible Errors, Random Error, at 100µl volume ≤0.25µl
    Gilson Maximum Permissible Errors, Random Error, at 50µl volume ≤0.20µl
      Customers Also Bought
      JMG Part No. 1152009
      JMG Part No. 1152003
      JMG Part No. 1152284
      JMG Part No. 1152281
      JMG Part No. 1152026

      Pipetman Classic™ - P200, 20 to 200µl

      OVERVIEW
      SPECIFICATIONS
      Brand: Gilson
      JMG No: 1152006
      Part No: F123601
      Type: Instrument
      Availability: In Stock

      PIPETMAN Classic™: The Incarnation of Gilson's Reliability, the World Pipetting Standard!

      The Pipetting Standard - Gilson's PIPETMAN Classic is designed and manufactured to provide you with a range of robust, accurate and precise pipettes. The PIPETMAN Classic is a fully adjustable, air-displacement pipette with the selected volume shown on a digital indicator (volumeter).

      Your Benefits
      Premium Robustness

      • Long product life and high resistance to agressive chemicals thanks to its stainless-steel and PVDF components.
      • Air-tight seal with unique "dry seal" technology (grease-free).

      Accuracy & Precision

      • Performance exceeding ISO recommendations by an average of 50%.
      • PIPETMAN P5000 and PIPETMAN P10ml are safer and more accurate than glass pipettes.

      Applications

      • PIPETMAN P2 and P10 models are ideal for molecular biology techniques (PCR, DNA sequencing, etc).
      • PIPETMAN P20, P100, P200, and P1000 models are suited for small-volume dispensing of aqueous fluids of moderate viscosity and density (molecular biology, immunology, etc).
      • PIPETMAN P5000 and P10ml models are ideal for large-volume dispensing of aqueous fluids of moderate viscosity and density.

      More About the Features

      • Tip-holder and tip-ejector are fully autoclavable to avoid cross-contamination.
      • P2 and P10 are equipped with a dual position tip ejector allowing the use of PIPETMAN DIAMOND D10 (short tip) and DL10 (long tip).
      • PIPETMAN P5000 and P10ml are equipped with a polyethylene filter that prolongs piston life and prevents contamination.

      Reliability
      Gilson's standards are even more stringent than those required by governing bodies: On average, PIPETMAN permissible errors are 2 times better than those recommended by ISO 8655!

      Our pipette manufacturing plant has its own accredited calibration laboratory to control the accuracy and precision of each and every Gilson pipette. Gilson pipettes are individually calibrated and delivered with a performance check report. Each pipette bears an engraved identification number for traceability.

      Decontamination & Autoclaving
      Your pipette could be contaminated accidentally. The most frequently contaminated pipette parts are the tip-ejector and tip-holder.

      For this reason, each and every Gilson PIPETMAN has autoclavable lower parts.

      Autoclaving
      Tip-ejector, tip-holder and connecting nut can be sterilised in the laboratory under the following conditions: Moist heat/121°C/20 minutes/1 bar.

      Decontamination
      For maintenance and decontamination procedures, please refer to the related PIPETMAN user's guide.

      Service
      Gilson believe that the quality of their pipettes must be matched by the quality of their service. That is why John Morris Scientific operate a Gilson-authorised service centre. This repair and calibration centre duplicates the conditions of Gilson's own factory, with controlled environments and regular inspections. Qualified technicians at our centre, having completed extensive training by Gilson, are specialists in the repair, calibration, and operation of Gilson products.

      Compliance with Standards
      ISO standards and Good Laboratory Practice (GLP) require that laboratories perform regular inspections and calibration certification. Whatever your requirements - ISO standards, GLP guidelines, metrology - our specialists can help you implement procedures that are suitable for your applications.

       

       

       

       

       

       

       

       

       


       

      Minimal Volume 20µl
      Nominal Volume 200µl
      ISO-8655 Permissible Errors, Systematic Error ±1.60µl
      ISO-8655 Permissible Errors, Random Error ≤0.60µl
      Gilson Maximum Permissible Errors, Systematic Error, at 200µl volume ±1.60µl
      Gilson Maximum Permissible Errors, Random Error, at 200µl volume ≤0.30µl
      Gilson Maximum Permissible Errors, Systematic Error, at 100µl volume ±0.80µl
      Gilson Maximum Permissible Errors, Systematic Error, at 50µl volume ±0.50µl
      Gilson Maximum Permissible Errors, Random Error, at 100µl volume ≤0.25µl
      Gilson Maximum Permissible Errors, Random Error, at 50µl volume ≤0.20µl
        OVERVIEW
        SPECIFICATIONS
        Brand: Gilson
        JMG No: 1152006
        Part No: F123601
        Type: Instrument
        Availability: In Stock

        PIPETMAN Classic™: The Incarnation of Gilson's Reliability, the World Pipetting Standard!

        The Pipetting Standard - Gilson's PIPETMAN Classic is designed and manufactured to provide you with a range of robust, accurate and precise pipettes. The PIPETMAN Classic is a fully adjustable, air-displacement pipette with the selected volume shown on a digital indicator (volumeter).

        Your Benefits
        Premium Robustness

        • Long product life and high resistance to agressive chemicals thanks to its stainless-steel and PVDF components.
        • Air-tight seal with unique "dry seal" technology (grease-free).

        Accuracy & Precision

        • Performance exceeding ISO recommendations by an average of 50%.
        • PIPETMAN P5000 and PIPETMAN P10ml are safer and more accurate than glass pipettes.

        Applications

        • PIPETMAN P2 and P10 models are ideal for molecular biology techniques (PCR, DNA sequencing, etc).
        • PIPETMAN P20, P100, P200, and P1000 models are suited for small-volume dispensing of aqueous fluids of moderate viscosity and density (molecular biology, immunology, etc).
        • PIPETMAN P5000 and P10ml models are ideal for large-volume dispensing of aqueous fluids of moderate viscosity and density.

        More About the Features

        • Tip-holder and tip-ejector are fully autoclavable to avoid cross-contamination.
        • P2 and P10 are equipped with a dual position tip ejector allowing the use of PIPETMAN DIAMOND D10 (short tip) and DL10 (long tip).
        • PIPETMAN P5000 and P10ml are equipped with a polyethylene filter that prolongs piston life and prevents contamination.

        Reliability
        Gilson's standards are even more stringent than those required by governing bodies: On average, PIPETMAN permissible errors are 2 times better than those recommended by ISO 8655!

        Our pipette manufacturing plant has its own accredited calibration laboratory to control the accuracy and precision of each and every Gilson pipette. Gilson pipettes are individually calibrated and delivered with a performance check report. Each pipette bears an engraved identification number for traceability.

        Decontamination & Autoclaving
        Your pipette could be contaminated accidentally. The most frequently contaminated pipette parts are the tip-ejector and tip-holder.

        For this reason, each and every Gilson PIPETMAN has autoclavable lower parts.

        Autoclaving
        Tip-ejector, tip-holder and connecting nut can be sterilised in the laboratory under the following conditions: Moist heat/121°C/20 minutes/1 bar.

        Decontamination
        For maintenance and decontamination procedures, please refer to the related PIPETMAN user's guide.

        Service
        Gilson believe that the quality of their pipettes must be matched by the quality of their service. That is why John Morris Scientific operate a Gilson-authorised service centre. This repair and calibration centre duplicates the conditions of Gilson's own factory, with controlled environments and regular inspections. Qualified technicians at our centre, having completed extensive training by Gilson, are specialists in the repair, calibration, and operation of Gilson products.

        Compliance with Standards
        ISO standards and Good Laboratory Practice (GLP) require that laboratories perform regular inspections and calibration certification. Whatever your requirements - ISO standards, GLP guidelines, metrology - our specialists can help you implement procedures that are suitable for your applications.

         

         

         

         

         

         

         

         

         


         

        Minimal Volume 20µl
        Nominal Volume 200µl
        ISO-8655 Permissible Errors, Systematic Error ±1.60µl
        ISO-8655 Permissible Errors, Random Error ≤0.60µl
        Gilson Maximum Permissible Errors, Systematic Error, at 200µl volume ±1.60µl
        Gilson Maximum Permissible Errors, Random Error, at 200µl volume ≤0.30µl
        Gilson Maximum Permissible Errors, Systematic Error, at 100µl volume ±0.80µl
        Gilson Maximum Permissible Errors, Systematic Error, at 50µl volume ±0.50µl
        Gilson Maximum Permissible Errors, Random Error, at 100µl volume ≤0.25µl
        Gilson Maximum Permissible Errors, Random Error, at 50µl volume ≤0.20µl
          $344 AUD (Ex. GST)
          Qty:
          Enquiry sent successfully
          Product Enquiry
          Customers Also Bought
          JMG Part No. 1152009
          JMG Part No. 1152003
          JMG Part No. 1152284
          JMG Part No. 1152281
          JMG Part No. 1152026