$156 AUD (Ex. GST)
Qty:
Enquiry sent successfully
Product Enquiry
OVERVIEW
SPECIFICATIONS
Brand: Gilson
JMG No: 1152670
Part No: F171703
Type: Instrument
Availability: In Stock

DIAMOND® Filter Tips: Pure Performance Tips for PIPETMAN®
DIAMOND filter tips are designed, developed, and manufactured in order to fit Gilson pipettes perfectly. They ensure optimal performance of your PIPETMAN pipette across the full volume range. They play a critical role in preventing aerosol-borne contamination.


Your Benefits
Accuracy & Precision

  • Optimised geometry and pure polypropylene material ensure complete dispensing for consistent results.
  • The use of Gilson's pipetting system guarantees accuracy and precision.

Contamination-Free

  • No risk of contamination: DIAMOND Tips are manufactured in a clean room.
  • Gamma ray sterilised. Indicator dots used on Gilson's products undergo an irreversible color change upon sterilisation.
  • Guaranteed free of DNA, RNA, DNase, RNase, ATP, Pyrogens and trace metals.

High Quality

  • Full traceability from the mold to the bench guaranteed.
  • Easy identification with color-coded packaging.

Accuracy & Precision
Superior Accuracy and Precision Guaranteed
"The maximum permissible errors always apply to the total pipetting system of piston pipette and tip. When using pipette tips not delivered by the pipette supplier, the supplier’s declaration or certificate of conformity does not apply” (ISO 8655-2)."

Diamond Tip Geometry Delivers Maximum Accuracy
DIAMOND Tips guarantee that Gilson's pipetting system meet our specified tolerances and deliver consistent results over time.


Results obtained in the Gilson ISO 17025 COFRAC accredited laboratory from 10 measurements of 1 µL of water at 21°C using a PIPETMAN P10.

Adding Comfort While Fitting and Ejecting Tips
Loose tip fitting is a major cause of bad performance. Specifically designed for Gilson pipettes, the diameter of the tip-collar of Gilson DIAMOND Tips is calculated to fit the tip-holder perfectly.

Best Match Between Pipette and Tips Reduces the Strain to Fit and Eject Tips
With DIAMOND Tips, no need to jam them on "extra tight" - use of excessive force that causes muscular stress and fatigue to the arm and shoulder is greatly reduced. As a result, thumb force to eject tips is minimal.

Pure Polypropolene Ensures No Contamination and Complete Dispensing
DIAMOND Tips are made from the highest-grade virgin polypropylene to prevent contamination of your experiments.

This polypropylene has high hydrophobic properties to ensure the lowest possible retention, no matter what liquid is pipetted.

Quality
Traceability: Fully traceable from the mold to your laboratory bench

  • Gilson logo means genuine DIAMOND Tips.
  • Identification number guarantees the manufacturing quality of the tips.
  • Batch number on each pack and rack.

Color-coded packaging

  • Volume recognition at a glance.
  • Helps prevent errors in the stock room and in the laboratory.

Prevention of Contamination

  • Clean room production.
  • Free of trace metals.
  • High quality and efficient filter: High-density polyethylene filter with a porosity designed to provide an effective barrier against aerosols generated by pipetting tasks. DIAMOND Filter tips contain no sealing additives which can be released into your sample.



Sterilised Tips

  • Free of biological contaminants: Free of detectable DNA, RNA, DNase, RNase, ATP, Pyrogens and trace metals.
  • Sterility assurance level: Sterility Assurance Level (SAL) of 10-6 is achieved by gamma irradiation. To download a copy of the biological contaminant certificate with batch number, please click here.
  • Optimised packaging: All packs are wrapped in medical device quality plastic. Indicator dots used on Gilson's products undergo an irreversible color change upon sterilisation. Orange gamma dots turn red when products have been properly exposed.

Manual Liquid Handling Catalog
 

Volume Range 200µl-1000µl
    OVERVIEW
    SPECIFICATIONS
    Brand: Gilson
    JMG No: 1152670
    Part No: F171703
    Type: Instrument
    Availability: In Stock

    DIAMOND® Filter Tips: Pure Performance Tips for PIPETMAN®
    DIAMOND filter tips are designed, developed, and manufactured in order to fit Gilson pipettes perfectly. They ensure optimal performance of your PIPETMAN pipette across the full volume range. They play a critical role in preventing aerosol-borne contamination.


    Your Benefits
    Accuracy & Precision

    • Optimised geometry and pure polypropylene material ensure complete dispensing for consistent results.
    • The use of Gilson's pipetting system guarantees accuracy and precision.

    Contamination-Free

    • No risk of contamination: DIAMOND Tips are manufactured in a clean room.
    • Gamma ray sterilised. Indicator dots used on Gilson's products undergo an irreversible color change upon sterilisation.
    • Guaranteed free of DNA, RNA, DNase, RNase, ATP, Pyrogens and trace metals.

    High Quality

    • Full traceability from the mold to the bench guaranteed.
    • Easy identification with color-coded packaging.

    Accuracy & Precision
    Superior Accuracy and Precision Guaranteed
    "The maximum permissible errors always apply to the total pipetting system of piston pipette and tip. When using pipette tips not delivered by the pipette supplier, the supplier’s declaration or certificate of conformity does not apply” (ISO 8655-2)."

    Diamond Tip Geometry Delivers Maximum Accuracy
    DIAMOND Tips guarantee that Gilson's pipetting system meet our specified tolerances and deliver consistent results over time.


    Results obtained in the Gilson ISO 17025 COFRAC accredited laboratory from 10 measurements of 1 µL of water at 21°C using a PIPETMAN P10.

    Adding Comfort While Fitting and Ejecting Tips
    Loose tip fitting is a major cause of bad performance. Specifically designed for Gilson pipettes, the diameter of the tip-collar of Gilson DIAMOND Tips is calculated to fit the tip-holder perfectly.

    Best Match Between Pipette and Tips Reduces the Strain to Fit and Eject Tips
    With DIAMOND Tips, no need to jam them on "extra tight" - use of excessive force that causes muscular stress and fatigue to the arm and shoulder is greatly reduced. As a result, thumb force to eject tips is minimal.

    Pure Polypropolene Ensures No Contamination and Complete Dispensing
    DIAMOND Tips are made from the highest-grade virgin polypropylene to prevent contamination of your experiments.

    This polypropylene has high hydrophobic properties to ensure the lowest possible retention, no matter what liquid is pipetted.

    Quality
    Traceability: Fully traceable from the mold to your laboratory bench

    • Gilson logo means genuine DIAMOND Tips.
    • Identification number guarantees the manufacturing quality of the tips.
    • Batch number on each pack and rack.

    Color-coded packaging

    • Volume recognition at a glance.
    • Helps prevent errors in the stock room and in the laboratory.

    Prevention of Contamination

    • Clean room production.
    • Free of trace metals.
    • High quality and efficient filter: High-density polyethylene filter with a porosity designed to provide an effective barrier against aerosols generated by pipetting tasks. DIAMOND Filter tips contain no sealing additives which can be released into your sample.



    Sterilised Tips

    • Free of biological contaminants: Free of detectable DNA, RNA, DNase, RNase, ATP, Pyrogens and trace metals.
    • Sterility assurance level: Sterility Assurance Level (SAL) of 10-6 is achieved by gamma irradiation. To download a copy of the biological contaminant certificate with batch number, please click here.
    • Optimised packaging: All packs are wrapped in medical device quality plastic. Indicator dots used on Gilson's products undergo an irreversible color change upon sterilisation. Orange gamma dots turn red when products have been properly exposed.

    Manual Liquid Handling Catalog
     

    Volume Range 200µl-1000µl
      Customers Also Bought
      JMG Part No. 1152441
      JMG Part No. 1152652
      JMG Part No. 1152665
      JMG Part No. 1152648
      JMG Part No. 1152657

      Diamond Filter Tips, sterilised, DF1000, 10 tipacks of 96 racked tips, box of 960

      OVERVIEW
      SPECIFICATIONS
      Brand: Gilson
      JMG No: 1152670
      Part No: F171703
      Type: Instrument
      Availability: In Stock

      DIAMOND® Filter Tips: Pure Performance Tips for PIPETMAN®
      DIAMOND filter tips are designed, developed, and manufactured in order to fit Gilson pipettes perfectly. They ensure optimal performance of your PIPETMAN pipette across the full volume range. They play a critical role in preventing aerosol-borne contamination.


      Your Benefits
      Accuracy & Precision

      • Optimised geometry and pure polypropylene material ensure complete dispensing for consistent results.
      • The use of Gilson's pipetting system guarantees accuracy and precision.

      Contamination-Free

      • No risk of contamination: DIAMOND Tips are manufactured in a clean room.
      • Gamma ray sterilised. Indicator dots used on Gilson's products undergo an irreversible color change upon sterilisation.
      • Guaranteed free of DNA, RNA, DNase, RNase, ATP, Pyrogens and trace metals.

      High Quality

      • Full traceability from the mold to the bench guaranteed.
      • Easy identification with color-coded packaging.

      Accuracy & Precision
      Superior Accuracy and Precision Guaranteed
      "The maximum permissible errors always apply to the total pipetting system of piston pipette and tip. When using pipette tips not delivered by the pipette supplier, the supplier’s declaration or certificate of conformity does not apply” (ISO 8655-2)."

      Diamond Tip Geometry Delivers Maximum Accuracy
      DIAMOND Tips guarantee that Gilson's pipetting system meet our specified tolerances and deliver consistent results over time.


      Results obtained in the Gilson ISO 17025 COFRAC accredited laboratory from 10 measurements of 1 µL of water at 21°C using a PIPETMAN P10.

      Adding Comfort While Fitting and Ejecting Tips
      Loose tip fitting is a major cause of bad performance. Specifically designed for Gilson pipettes, the diameter of the tip-collar of Gilson DIAMOND Tips is calculated to fit the tip-holder perfectly.

      Best Match Between Pipette and Tips Reduces the Strain to Fit and Eject Tips
      With DIAMOND Tips, no need to jam them on "extra tight" - use of excessive force that causes muscular stress and fatigue to the arm and shoulder is greatly reduced. As a result, thumb force to eject tips is minimal.

      Pure Polypropolene Ensures No Contamination and Complete Dispensing
      DIAMOND Tips are made from the highest-grade virgin polypropylene to prevent contamination of your experiments.

      This polypropylene has high hydrophobic properties to ensure the lowest possible retention, no matter what liquid is pipetted.

      Quality
      Traceability: Fully traceable from the mold to your laboratory bench

      • Gilson logo means genuine DIAMOND Tips.
      • Identification number guarantees the manufacturing quality of the tips.
      • Batch number on each pack and rack.

      Color-coded packaging

      • Volume recognition at a glance.
      • Helps prevent errors in the stock room and in the laboratory.

      Prevention of Contamination

      • Clean room production.
      • Free of trace metals.
      • High quality and efficient filter: High-density polyethylene filter with a porosity designed to provide an effective barrier against aerosols generated by pipetting tasks. DIAMOND Filter tips contain no sealing additives which can be released into your sample.



      Sterilised Tips

      • Free of biological contaminants: Free of detectable DNA, RNA, DNase, RNase, ATP, Pyrogens and trace metals.
      • Sterility assurance level: Sterility Assurance Level (SAL) of 10-6 is achieved by gamma irradiation. To download a copy of the biological contaminant certificate with batch number, please click here.
      • Optimised packaging: All packs are wrapped in medical device quality plastic. Indicator dots used on Gilson's products undergo an irreversible color change upon sterilisation. Orange gamma dots turn red when products have been properly exposed.

      Manual Liquid Handling Catalog
       

      Volume Range 200µl-1000µl
        OVERVIEW
        SPECIFICATIONS
        Brand: Gilson
        JMG No: 1152670
        Part No: F171703
        Type: Instrument
        Availability: In Stock

        DIAMOND® Filter Tips: Pure Performance Tips for PIPETMAN®
        DIAMOND filter tips are designed, developed, and manufactured in order to fit Gilson pipettes perfectly. They ensure optimal performance of your PIPETMAN pipette across the full volume range. They play a critical role in preventing aerosol-borne contamination.


        Your Benefits
        Accuracy & Precision

        • Optimised geometry and pure polypropylene material ensure complete dispensing for consistent results.
        • The use of Gilson's pipetting system guarantees accuracy and precision.

        Contamination-Free

        • No risk of contamination: DIAMOND Tips are manufactured in a clean room.
        • Gamma ray sterilised. Indicator dots used on Gilson's products undergo an irreversible color change upon sterilisation.
        • Guaranteed free of DNA, RNA, DNase, RNase, ATP, Pyrogens and trace metals.

        High Quality

        • Full traceability from the mold to the bench guaranteed.
        • Easy identification with color-coded packaging.

        Accuracy & Precision
        Superior Accuracy and Precision Guaranteed
        "The maximum permissible errors always apply to the total pipetting system of piston pipette and tip. When using pipette tips not delivered by the pipette supplier, the supplier’s declaration or certificate of conformity does not apply” (ISO 8655-2)."

        Diamond Tip Geometry Delivers Maximum Accuracy
        DIAMOND Tips guarantee that Gilson's pipetting system meet our specified tolerances and deliver consistent results over time.


        Results obtained in the Gilson ISO 17025 COFRAC accredited laboratory from 10 measurements of 1 µL of water at 21°C using a PIPETMAN P10.

        Adding Comfort While Fitting and Ejecting Tips
        Loose tip fitting is a major cause of bad performance. Specifically designed for Gilson pipettes, the diameter of the tip-collar of Gilson DIAMOND Tips is calculated to fit the tip-holder perfectly.

        Best Match Between Pipette and Tips Reduces the Strain to Fit and Eject Tips
        With DIAMOND Tips, no need to jam them on "extra tight" - use of excessive force that causes muscular stress and fatigue to the arm and shoulder is greatly reduced. As a result, thumb force to eject tips is minimal.

        Pure Polypropolene Ensures No Contamination and Complete Dispensing
        DIAMOND Tips are made from the highest-grade virgin polypropylene to prevent contamination of your experiments.

        This polypropylene has high hydrophobic properties to ensure the lowest possible retention, no matter what liquid is pipetted.

        Quality
        Traceability: Fully traceable from the mold to your laboratory bench

        • Gilson logo means genuine DIAMOND Tips.
        • Identification number guarantees the manufacturing quality of the tips.
        • Batch number on each pack and rack.

        Color-coded packaging

        • Volume recognition at a glance.
        • Helps prevent errors in the stock room and in the laboratory.

        Prevention of Contamination

        • Clean room production.
        • Free of trace metals.
        • High quality and efficient filter: High-density polyethylene filter with a porosity designed to provide an effective barrier against aerosols generated by pipetting tasks. DIAMOND Filter tips contain no sealing additives which can be released into your sample.



        Sterilised Tips

        • Free of biological contaminants: Free of detectable DNA, RNA, DNase, RNase, ATP, Pyrogens and trace metals.
        • Sterility assurance level: Sterility Assurance Level (SAL) of 10-6 is achieved by gamma irradiation. To download a copy of the biological contaminant certificate with batch number, please click here.
        • Optimised packaging: All packs are wrapped in medical device quality plastic. Indicator dots used on Gilson's products undergo an irreversible color change upon sterilisation. Orange gamma dots turn red when products have been properly exposed.

        Manual Liquid Handling Catalog
         

        Volume Range 200µl-1000µl
          $156 AUD (Ex. GST)
          Qty:
          Enquiry sent successfully
          Product Enquiry
          Customers Also Bought
          JMG Part No. 1152441
          JMG Part No. 1152652
          JMG Part No. 1152665
          JMG Part No. 1152648
          JMG Part No. 1152657