$188 AUD (Ex. GST)
Qty:
Enquiry sent successfully
Product Enquiry
OVERVIEW
SPECIFICATIONS
DOWNLOADS
Q&A
Brand: Masterflex
JMG No: 1130573
Part No: 96410-14
UNSPSC: 41105100
Type: Instrument
Availability: In Stock
  • Ensure optimal performance from your Masterflex® pump
  • Slightly greater clarity than peroxide-cured tubing
  • Smooth surfaces; lower protein binding levels
  • Fewer potential leachables
  • Ideal for pharmaceutical and biotechnology use

Applications: Pharmaceutical, biotech, peristaltic pumping, and food applications.
Characteristics: Excellent heat resistance, low compression set, odorless, nontoxic. Translucent

Masterflex L/S pump tubing is manufactured to extremely close tolerances that match our L/S pump heads, ensuring accurate, repeatable flow and long tubing life. Our pump tubing is factory-tested and optically inspected to provide the best performance from your peristaltic pump.

Sterilization Method Autoclave
Sterilization Method Autoclave Yes
Tubing formulation Silicone (platinum-cured)
Length per Pack (FeetShort) 25
Max pressure (psi) 40
Min Temperature (DegreeF) -58
Max Temperature (Dynamic) (DegreeC) 100
Max Vacuum (InchHg) 26
Min Temperature (Dynamic) (DegreeC) -40
Pump Series L/S
Suction Lift (ftH2O) 29
Tubing ID (mm) 1.6
Length per pack (m) 7.6
Max Flow Rate (mLmin) 130
Max Temperature (DegreeC) 230
Max Temperature (DegreeF) 446
Max Vacuum (mmHg) 660
Min Temperature (DegreeC) -50
Suction Lift (mH2O) 8.8
Tubing ID (InchShort) 0.063
Hose Barb Size (InchShort) 0.0625
L/S Masterflex tubing size 14
Max pressure (bar) 2.7
Max Temperature (Dynamic) (DegreeF) 212
Min Temperature (Dynamic) (DegreeF) -40
Resin certification
Description platinum-cured silicone tubing, L/S 14, 25 ft.
Can this tubing be sterilized by ethylene oxide?
Answer
No, this formulation of platinum-cured silicone has not gone through the validation process to provide sufficient data about complete outgassing of residual ETO and other ETO products. We suggest the BioPharm silicone if ETO sterilization is needed. Please see part number 96420-14 for this same, L/S 14, size in the BioPharm silicone composition which has undergone sufficient validation testing for the ETO sterilization method.Answered on 11/21/2011 by Jen from Technical Support
Can you provide MSDS and Certificates of Analysis for your tubing?
Answer
Yes, many of our tubing compositions have a certificate of compliance that can be provided based upon the lot number. The certificate and MSDS may both be requested by email or call to our technical department.Answered on 2/9/2011 by Jen from Technical Support
Is there some kind of tube splitter available for this tube? (a sort of attachment which makes it possible to divide the flow in 2 or more channels)
Answer
A "Y" type fitting will split a single channel into two, please see part number 30614-04 to fit the L/S size tubing for example.If even more channels are needed to stem from a single tube, multiple "Y's" can be used or perhaps a manifold system should be set up.Answered on 4/10/2012 by Jen from Technical Support
What is the hardness of tubing 96410-14?
Answer
This tubing is listed to have a durometer of 60(A).Answered on 9/2/2009 by Jen from Technical Support
What is the inner diameter of the L/s 14?
Answer
The inner diameter is 1.6 mm or 1/16 inch.Answered on 3/15/2011 by Jen from Technical Support
What is the outer diameter of this tubing?
Answer
The outer diameter is proprietary along with the wall thickness and is not published for any of he Masterflex tubing options.Answered on 6/20/2013 by Jose from Technical Support
What is the ph range for this tubing? More specifically what is the life expactantcy when using HCL?
Answer
Silicone tubing is not compatible with hydrochloric acid. We do not suggest using it at all. pH is not what determines chemical compatibility, the chemical itself does. Please contact our technical application specialists for additional assistance (contact information can be found in the "contact us" section on the web page).Answered on 5/20/2010 by Jen from Technical Support
Will this tube fit on a Easy-load pump head #7518-00?Thank youX
Answer
Yes, that pump head accepts L/S size 14 tubing.Answered on 12/3/2009 by Jen from Technical Support
You mention that your "Biopharm plus" platinum cured tubing has a longer life expectancy then other platinum cured tubings (up to five times)What is the life expectancy of your tubing in a WM102 pump?
Answer
We do not have expected life expectancy for any tubing with any other pumps other than our own Masterflex pumps heads and pump drives.Answered on 12/4/2013 by Jose from Technical Support
OVERVIEW
SPECIFICATIONS
DOWNLOADS
Q&A
Brand: Masterflex
JMG No: 1130573
Part No: 96410-14
UNSPSC: 41105100
Type: Instrument
Availability: In Stock
  • Ensure optimal performance from your Masterflex® pump
  • Slightly greater clarity than peroxide-cured tubing
  • Smooth surfaces; lower protein binding levels
  • Fewer potential leachables
  • Ideal for pharmaceutical and biotechnology use

Applications: Pharmaceutical, biotech, peristaltic pumping, and food applications.
Characteristics: Excellent heat resistance, low compression set, odorless, nontoxic. Translucent

Masterflex L/S pump tubing is manufactured to extremely close tolerances that match our L/S pump heads, ensuring accurate, repeatable flow and long tubing life. Our pump tubing is factory-tested and optically inspected to provide the best performance from your peristaltic pump.

Sterilization Method Autoclave
Sterilization Method Autoclave Yes
Tubing formulation Silicone (platinum-cured)
Length per Pack (FeetShort) 25
Max pressure (psi) 40
Min Temperature (DegreeF) -58
Max Temperature (Dynamic) (DegreeC) 100
Max Vacuum (InchHg) 26
Min Temperature (Dynamic) (DegreeC) -40
Pump Series L/S
Suction Lift (ftH2O) 29
Tubing ID (mm) 1.6
Length per pack (m) 7.6
Max Flow Rate (mLmin) 130
Max Temperature (DegreeC) 230
Max Temperature (DegreeF) 446
Max Vacuum (mmHg) 660
Min Temperature (DegreeC) -50
Suction Lift (mH2O) 8.8
Tubing ID (InchShort) 0.063
Hose Barb Size (InchShort) 0.0625
L/S Masterflex tubing size 14
Max pressure (bar) 2.7
Max Temperature (Dynamic) (DegreeF) 212
Min Temperature (Dynamic) (DegreeF) -40
Resin certification
Description platinum-cured silicone tubing, L/S 14, 25 ft.
Can this tubing be sterilized by ethylene oxide?
Answer
No, this formulation of platinum-cured silicone has not gone through the validation process to provide sufficient data about complete outgassing of residual ETO and other ETO products. We suggest the BioPharm silicone if ETO sterilization is needed. Please see part number 96420-14 for this same, L/S 14, size in the BioPharm silicone composition which has undergone sufficient validation testing for the ETO sterilization method.Answered on 11/21/2011 by Jen from Technical Support
Can you provide MSDS and Certificates of Analysis for your tubing?
Answer
Yes, many of our tubing compositions have a certificate of compliance that can be provided based upon the lot number. The certificate and MSDS may both be requested by email or call to our technical department.Answered on 2/9/2011 by Jen from Technical Support
Is there some kind of tube splitter available for this tube? (a sort of attachment which makes it possible to divide the flow in 2 or more channels)
Answer
A "Y" type fitting will split a single channel into two, please see part number 30614-04 to fit the L/S size tubing for example.If even more channels are needed to stem from a single tube, multiple "Y's" can be used or perhaps a manifold system should be set up.Answered on 4/10/2012 by Jen from Technical Support
What is the hardness of tubing 96410-14?
Answer
This tubing is listed to have a durometer of 60(A).Answered on 9/2/2009 by Jen from Technical Support
What is the inner diameter of the L/s 14?
Answer
The inner diameter is 1.6 mm or 1/16 inch.Answered on 3/15/2011 by Jen from Technical Support
What is the outer diameter of this tubing?
Answer
The outer diameter is proprietary along with the wall thickness and is not published for any of he Masterflex tubing options.Answered on 6/20/2013 by Jose from Technical Support
What is the ph range for this tubing? More specifically what is the life expactantcy when using HCL?
Answer
Silicone tubing is not compatible with hydrochloric acid. We do not suggest using it at all. pH is not what determines chemical compatibility, the chemical itself does. Please contact our technical application specialists for additional assistance (contact information can be found in the "contact us" section on the web page).Answered on 5/20/2010 by Jen from Technical Support
Will this tube fit on a Easy-load pump head #7518-00?Thank youX
Answer
Yes, that pump head accepts L/S size 14 tubing.Answered on 12/3/2009 by Jen from Technical Support
You mention that your "Biopharm plus" platinum cured tubing has a longer life expectancy then other platinum cured tubings (up to five times)What is the life expectancy of your tubing in a WM102 pump?
Answer
We do not have expected life expectancy for any tubing with any other pumps other than our own Masterflex pumps heads and pump drives.Answered on 12/4/2013 by Jose from Technical Support
Customers Also Bought
JMG Part No. 1076227
JMG Part No. 1076205
JMG Part No. 1130572
JMG Part No. 1015188
JMG Part No. 1076207
Related Products
JMG Part No. 1012276

Masterflex platinum-cured silicone tubing, L/S 14, 25 ft.

OVERVIEW
SPECIFICATIONS
DOWNLOADS
Q&A
Brand: Masterflex
JMG No: 1130573
Part No: 96410-14
UNSPSC: 41105100
Type: Instrument
Availability: In Stock
  • Ensure optimal performance from your Masterflex® pump
  • Slightly greater clarity than peroxide-cured tubing
  • Smooth surfaces; lower protein binding levels
  • Fewer potential leachables
  • Ideal for pharmaceutical and biotechnology use

Applications: Pharmaceutical, biotech, peristaltic pumping, and food applications.
Characteristics: Excellent heat resistance, low compression set, odorless, nontoxic. Translucent

Masterflex L/S pump tubing is manufactured to extremely close tolerances that match our L/S pump heads, ensuring accurate, repeatable flow and long tubing life. Our pump tubing is factory-tested and optically inspected to provide the best performance from your peristaltic pump.

Sterilization Method Autoclave
Sterilization Method Autoclave Yes
Tubing formulation Silicone (platinum-cured)
Length per Pack (FeetShort) 25
Max pressure (psi) 40
Min Temperature (DegreeF) -58
Max Temperature (Dynamic) (DegreeC) 100
Max Vacuum (InchHg) 26
Min Temperature (Dynamic) (DegreeC) -40
Pump Series L/S
Suction Lift (ftH2O) 29
Tubing ID (mm) 1.6
Length per pack (m) 7.6
Max Flow Rate (mLmin) 130
Max Temperature (DegreeC) 230
Max Temperature (DegreeF) 446
Max Vacuum (mmHg) 660
Min Temperature (DegreeC) -50
Suction Lift (mH2O) 8.8
Tubing ID (InchShort) 0.063
Hose Barb Size (InchShort) 0.0625
L/S Masterflex tubing size 14
Max pressure (bar) 2.7
Max Temperature (Dynamic) (DegreeF) 212
Min Temperature (Dynamic) (DegreeF) -40
Resin certification
Description platinum-cured silicone tubing, L/S 14, 25 ft.
Can this tubing be sterilized by ethylene oxide?
Answer
No, this formulation of platinum-cured silicone has not gone through the validation process to provide sufficient data about complete outgassing of residual ETO and other ETO products. We suggest the BioPharm silicone if ETO sterilization is needed. Please see part number 96420-14 for this same, L/S 14, size in the BioPharm silicone composition which has undergone sufficient validation testing for the ETO sterilization method.Answered on 11/21/2011 by Jen from Technical Support
Can you provide MSDS and Certificates of Analysis for your tubing?
Answer
Yes, many of our tubing compositions have a certificate of compliance that can be provided based upon the lot number. The certificate and MSDS may both be requested by email or call to our technical department.Answered on 2/9/2011 by Jen from Technical Support
Is there some kind of tube splitter available for this tube? (a sort of attachment which makes it possible to divide the flow in 2 or more channels)
Answer
A "Y" type fitting will split a single channel into two, please see part number 30614-04 to fit the L/S size tubing for example.If even more channels are needed to stem from a single tube, multiple "Y's" can be used or perhaps a manifold system should be set up.Answered on 4/10/2012 by Jen from Technical Support
What is the hardness of tubing 96410-14?
Answer
This tubing is listed to have a durometer of 60(A).Answered on 9/2/2009 by Jen from Technical Support
What is the inner diameter of the L/s 14?
Answer
The inner diameter is 1.6 mm or 1/16 inch.Answered on 3/15/2011 by Jen from Technical Support
What is the outer diameter of this tubing?
Answer
The outer diameter is proprietary along with the wall thickness and is not published for any of he Masterflex tubing options.Answered on 6/20/2013 by Jose from Technical Support
What is the ph range for this tubing? More specifically what is the life expactantcy when using HCL?
Answer
Silicone tubing is not compatible with hydrochloric acid. We do not suggest using it at all. pH is not what determines chemical compatibility, the chemical itself does. Please contact our technical application specialists for additional assistance (contact information can be found in the "contact us" section on the web page).Answered on 5/20/2010 by Jen from Technical Support
Will this tube fit on a Easy-load pump head #7518-00?Thank youX
Answer
Yes, that pump head accepts L/S size 14 tubing.Answered on 12/3/2009 by Jen from Technical Support
You mention that your "Biopharm plus" platinum cured tubing has a longer life expectancy then other platinum cured tubings (up to five times)What is the life expectancy of your tubing in a WM102 pump?
Answer
We do not have expected life expectancy for any tubing with any other pumps other than our own Masterflex pumps heads and pump drives.Answered on 12/4/2013 by Jose from Technical Support
OVERVIEW
SPECIFICATIONS
DOWNLOADS
Q&A
Brand: Masterflex
JMG No: 1130573
Part No: 96410-14
UNSPSC: 41105100
Type: Instrument
Availability: In Stock
  • Ensure optimal performance from your Masterflex® pump
  • Slightly greater clarity than peroxide-cured tubing
  • Smooth surfaces; lower protein binding levels
  • Fewer potential leachables
  • Ideal for pharmaceutical and biotechnology use

Applications: Pharmaceutical, biotech, peristaltic pumping, and food applications.
Characteristics: Excellent heat resistance, low compression set, odorless, nontoxic. Translucent

Masterflex L/S pump tubing is manufactured to extremely close tolerances that match our L/S pump heads, ensuring accurate, repeatable flow and long tubing life. Our pump tubing is factory-tested and optically inspected to provide the best performance from your peristaltic pump.

Sterilization Method Autoclave
Sterilization Method Autoclave Yes
Tubing formulation Silicone (platinum-cured)
Length per Pack (FeetShort) 25
Max pressure (psi) 40
Min Temperature (DegreeF) -58
Max Temperature (Dynamic) (DegreeC) 100
Max Vacuum (InchHg) 26
Min Temperature (Dynamic) (DegreeC) -40
Pump Series L/S
Suction Lift (ftH2O) 29
Tubing ID (mm) 1.6
Length per pack (m) 7.6
Max Flow Rate (mLmin) 130
Max Temperature (DegreeC) 230
Max Temperature (DegreeF) 446
Max Vacuum (mmHg) 660
Min Temperature (DegreeC) -50
Suction Lift (mH2O) 8.8
Tubing ID (InchShort) 0.063
Hose Barb Size (InchShort) 0.0625
L/S Masterflex tubing size 14
Max pressure (bar) 2.7
Max Temperature (Dynamic) (DegreeF) 212
Min Temperature (Dynamic) (DegreeF) -40
Resin certification
Description platinum-cured silicone tubing, L/S 14, 25 ft.
Can this tubing be sterilized by ethylene oxide?
Answer
No, this formulation of platinum-cured silicone has not gone through the validation process to provide sufficient data about complete outgassing of residual ETO and other ETO products. We suggest the BioPharm silicone if ETO sterilization is needed. Please see part number 96420-14 for this same, L/S 14, size in the BioPharm silicone composition which has undergone sufficient validation testing for the ETO sterilization method.Answered on 11/21/2011 by Jen from Technical Support
Can you provide MSDS and Certificates of Analysis for your tubing?
Answer
Yes, many of our tubing compositions have a certificate of compliance that can be provided based upon the lot number. The certificate and MSDS may both be requested by email or call to our technical department.Answered on 2/9/2011 by Jen from Technical Support
Is there some kind of tube splitter available for this tube? (a sort of attachment which makes it possible to divide the flow in 2 or more channels)
Answer
A "Y" type fitting will split a single channel into two, please see part number 30614-04 to fit the L/S size tubing for example.If even more channels are needed to stem from a single tube, multiple "Y's" can be used or perhaps a manifold system should be set up.Answered on 4/10/2012 by Jen from Technical Support
What is the hardness of tubing 96410-14?
Answer
This tubing is listed to have a durometer of 60(A).Answered on 9/2/2009 by Jen from Technical Support
What is the inner diameter of the L/s 14?
Answer
The inner diameter is 1.6 mm or 1/16 inch.Answered on 3/15/2011 by Jen from Technical Support
What is the outer diameter of this tubing?
Answer
The outer diameter is proprietary along with the wall thickness and is not published for any of he Masterflex tubing options.Answered on 6/20/2013 by Jose from Technical Support
What is the ph range for this tubing? More specifically what is the life expactantcy when using HCL?
Answer
Silicone tubing is not compatible with hydrochloric acid. We do not suggest using it at all. pH is not what determines chemical compatibility, the chemical itself does. Please contact our technical application specialists for additional assistance (contact information can be found in the "contact us" section on the web page).Answered on 5/20/2010 by Jen from Technical Support
Will this tube fit on a Easy-load pump head #7518-00?Thank youX
Answer
Yes, that pump head accepts L/S size 14 tubing.Answered on 12/3/2009 by Jen from Technical Support
You mention that your "Biopharm plus" platinum cured tubing has a longer life expectancy then other platinum cured tubings (up to five times)What is the life expectancy of your tubing in a WM102 pump?
Answer
We do not have expected life expectancy for any tubing with any other pumps other than our own Masterflex pumps heads and pump drives.Answered on 12/4/2013 by Jose from Technical Support
$188 AUD (Ex. GST)
Qty:
Enquiry sent successfully
Product Enquiry
Customers Also Bought
JMG Part No. 1076227
JMG Part No. 1076205
JMG Part No. 1130572
JMG Part No. 1015188
JMG Part No. 1076207
Related Products
JMG Part No. 1012276