Labconco, Purifier Logic+ Class II A2 Biological Safety Cabinet with 8" sash opening, UV, Service Fixture, Vacu-Pass Portal and Base Stand, 4' width_1694434
Representative image only

Labconco, Purifier Logic+ Class II A2 Biological Safety Cabinet with 8" sash opening, UV, Service Fixture, Vacu-Pass Portal and Base Stand, 4' width

Product SubcategoryClass II, Type A2 Biological Safety Cabinets
Nominal Width4'
Protection typeProduct and Personnel
Nominal Sash Opening8" (20 cm)
Built In OptionsUV Light, Valves (Air, Vacuum, etc.), Cord, Cable and Tubing Portal
Base StandIncluded
ConformanceADA, CE, NSF 49
Exhaust Volume319-396 CFM (with optional canopy)
LightingUltraviolet, LED
Service FixturesOne
Dimensions137.9 x 79.2 x 226.6-241.8 cm
Electrical230V, 50/60 Hz, 6A
Overview

Purifier Logic+ Class II, Type A2 Biosafety Cabinets provide personnel, product and environmental protection from hazardous particulates such as agents that require Biosafety Level 1, 2 or 3 containment. Other appropriate applications include work with antineoplastic drugs, genetic material, asbestos and additional substances that generate hazardous airborne particulates. All models are NSF-Listed. 

These biological safety cabinets are designed to discharge HEPA-filtered exhaust air directly into the laboratory, or into an exhaust system through the optional Canopy Connection. When canopy-connected, the biosafety cabinets may be used for applications involving minute quantities of volatile toxic chemicals and tracer amounts of radionuclides as an adjunct to microbiological research.

During operation, room air is drawn into the inlet grill. The air in the plenum beneath the work surface is a mixture of unfiltered room air and air that has just passed through the work area. This contaminated air is drawn by the blower through the back plenum of the cabinet, where approximately 70% of the air is recirculated through the supply HEPA filter and back over the work area. The balance of the contaminated air is discharged to the environment after passing through the exhaust HEPA filter. 

 

  • Product Subcategory: Class II, Type A2 Biological Safety Cabinets
  • Nominal Width: 4'
  • Protection Type: Product and Personnel
  • Nominal Sash Opening: 8" (20 cm)
  • Built In Options: UV Light, Valves (Air, Vacuum, etc.), Cord, Cable & Tubing Portal
  • Base Stand: Included
  • Conformance: ADA, CE, NSF 49
  • Exhaust Volume: 319-396 CFM (with optional canopy)
  • Lighting: Ultraviolet, LED
  • Service Fixtures: One
  • Dimensions metric: 137.9 x 79.2 x 226.6-241.8 cm
  • Electrical: 230V, 50/60 Hz, 6A